GAS SPECIFICATION
Gas type &
pressure
Heat input and orifice size marked (mm)
Auxillery Semi-rapid Rapid burner WOK
G20, 20 mbar,
G30, 29 mbar
1 кW
(73 g/h)
1,75 кW
(127 g/h)
2,5 кW
(210 g/h)
2,5 кW
(167 g/h)
ELECTRICAL CONNECTION
� This appliance must be earthed.
� This appliance is designed to be connected to a 220-240V, 50Hz-60Hz AC
electricity supply.
� The wires in the mains lead are coloured in accordance with the following
code:
Green/yellow = Earth
Blue = Neutral
Brown = Live
�The wire which is coloured green and yellow must be connected to
the terminal which is marked with the letter E or by the earth symbol.
GAS ADJUSTMENT
�Take precautions on the operations and adjustments to be carried
out when converting from one gas to another.
�Before you begin, turn off the gas and electricity supply to the
appliance.
�Change the injector of the burners.