Icom IC-775DSP [22/67] For dsp equipped type when operating afsk or sstv in ssb mode the

Содержание

2 INSTALLATION AND CONNECTIONS FSK and AFSK SSTV connections To connect a terminal unit TNC or scan converter refer the diagram below For RTTY operation The optional 250 Hz CW narrow filters may not pass RTTY signals Be sure to select the appropriate IF filters corresponding to the signal width For DSP equipped type When operating AFSK or SSTV in SSB mode the transmit 2 5 kHz low pass filter is activated at its P default setting p 42 According to the AFSK system modulation may become shallow or not occur at all Turn the PSN modulation OFF p 41 to cancel the transmit filter in this case FSK RTTY connection Terminal unit TU or Terminal Node Controller TNC Use RTTY mode for operation _ AC innut Ar inpUl Ground GND PTT r11 QAIIFI CM inmtf OUUuLvn IlipUl ni I T Keying ACC 1 socket Rear panel view Connect the SQUELCH line when required AFSK and SSTV connections Terminal Node Controller TNC or Scan converter Use SSB or FM mode for operation AFSK output AF input Ground GND PIT SQUELCH input ACC 1 socket Rear panel view Connect the SQUELCH line when required AFSK and SSTV connections via microphone connector Terminal Node Controller TNC or Scan converter Use SSB or FM mode for operation MIC connector Front panel view Connect the SQUELCH line when required When connected to the MIC connector MIC and AF control adjustment is required When connected to the MIC connector in a DATA mode turn the front panel data input in H set mode ON p 47 19