Icom IC-775DSP [61/67] Display

Содержание

TROUBLESHOOTING 9 PROBLEM TRANSMIT S The ANT switches do not function The antenna switches have not been activated Set the antenna switches in the H set p 45 mode to on or Aut Transmitting is impos sible The operating frequency is not set to a ham band Set the frequency to a ham band p 25 Output power is too low PWR is set too far counter clockwise Rotate PWR clockwise p 3 DRIVE is set too far counter clockwise Set DRIVE to center position p 36 MIC is set too far counterclockwise Set MIC to a suitable position p 3 The antenna is not connected pro perly Reconnect the antenna and check the ANT switch position p 15 The antenna feedline is cut or shorted Check the feedline and correct any improper conditions An antenna for another band is se lected Select an antenna suitable for the operating frequency P 2 The antenna is not properly tuned Push TUNER for 2 sec to manually tune the antenna p 39 RIT ZJTX function is activated Push RIT ZJTX to turn the function OFF p 7 DATA mode is selected Push the desired mode key once or twice p 5 Split frequecny function and or dual watch are activated Push SPLIT and or DUALWATCH to turn the function OFF pgs 6 33 35 Split function is not activated Push SPLIT to turn the function ON pgs 6 33 An incorrect transmit frequency is set Set the proper frequencies to the MAIN and SUB readouts p 38 Programmed subaudible tone fre quency is wrong Reset the frequency using H set p 46 mode MIC is rotated too far clockwise Set MIC to a suitable position p 3 DRIVE is rotated too far clockwise with the speech compressor ON Set DRIVE to a suitable position pgs 4 36 The displayed fre quency does not change properly The main and or sub dial lock func tions are activated Push MAIN and or SUB LOCK to deactivate the functions p 40 The internal CPU has malfunctioned Perform CPU resetting While pushing and holding CLEAR turn power ON p 21 Programmed scan does not stop Squelch is open Set SQL to the threshold point p 53 SQL is assigned to CW pitch and squelch is open Reset SQL control arrangement and set it to the threshold point p 43 Programmed scan does not start The same frequencies have been programmed in scan edge memory channels P1 and P2 Program different frequencies into scan edge memory channels P1 and P2 p 52 Memory scan does not start 2 or more memory channels have not been programmed Program 2 or more memory channels p 50 Select memory scan does not start 2 or more memory channels have not been designated as select channels Designate 2 or more memory chan nels as select channels for the scan p 54 No contact possible with another station Repeater cannot be ac cessed DISPLAY Transmitted signals are distorted SCAN POSSIBLE CAUSE 58