Connect the Equipment
USB and Serial
Data port
To use PowerChute software, connect a USB cable (not
supplied), to the USB and serial port.
Battery Backup
+ Surge
Protection
outlets
These outlets provide battery backup power to connected
equipment for a limited period of time during power outages
and voltage fluctuations.
The Battery Backup + Surge Protection outlets provide
battery power to connected equipment only when the Back-
UPS is turned on.
Connect critical equipment such as a computer, computer
monitor, modem or other data sensitive devices to these
outlets.
Do not connect aquarium equipment, laser printers, paper
shredders, sump pumps, or fans to these outlets as the
modified sine wave output of the Back-UPS may cause
these devices to experience a decrease in performance.
Do not connect surge protectors or extension cords to these
outlets.
Controlled
outlets
These outlets provide surge protection for connected
devices.
To conserve energy the Controlled by Master outlets will
disconnect from AC power whenever the device plugged
into the MASTER outlet is turned off or goes into Standby
or Hibernation mode.
Connect a printer, scanner or other noncritical devices that
do not require battery backup protection.
Surge
Protection
outlets
These outlets provide full-time protection for connected
equipment from power surges when the Back-UPS is turned
on or off.
The Surge Protection outlets do not provide battery backup
to connected equipment.
Connect a printer, scanner or other noncritical devices that
do not require battery backup protection.
AC Power
Input
Use the supplied power cable to connect the unit to AC power.
Data Port
Use the supplied RJ45/USB cable to connect the Back-UPS unit to a computer to install the software.
Circuit breaker
Use to reset the system after an overload condition has occurred causing the circuit breaker to trip.
Master outlet
Connect the master device to this outlet, in most cases, this will be the main computer.
In addition to providing battery backup power and surge protection, this outlet will signal the Controlled by Master outlets to
disconnect from AC power when the master device is either turned off or goes into Standby or Hibernation mode.
DSL/Modem/
FAX/Phone
Use an Ethernet cable to connect a modem to the I
N port, and a computer to the OUT port.
Wall Outlet
Connect the unit to a data line wall outlet
UK
bu0
52a
Содержание
40- Inventory safety and general information
- Es 550 700
- Connect the battery
- Operation manual back up
- Mm 6 0 in
- Inventory
- Inspect the package contents upon receipt notify the carrier and dealer if there is any damage read the safety guide supplied with this unit before installing the ups
- Inspect the package contents upon receipt notify the carrier and dealer if there is any damage
- Wall mounting template
- Wall mount installation
- Safety and general information
- Read the safety guide supplied with this unit before installing the ups
- Connect the equipment
- Software
- Powerchut
- Powerchute personal edition software
- Power saving feature
- Personal edition software
- Overview
- Operation
- Install powerchute software
- Install powerchut
- Compatibility
- Turn on the back ups
- Troubleshooting
- Status led indicator audible indicator on audible indicator terminates
- Status indicators
- Problem probable cause solution
- Specifications
- Replace the used battery with an apc by schneider electric approved battery replacement batteries can be ordered through the apc by schneider electric web site www apc com battery replacement parts are rbc110 for back ups be550 and rbc17 for back ups be700
- Replace battery
- Protection and filter
- Problem probable cause solution
- Physical
- Output
- Deliver the used battery to a recycling facility
- Battery
- Service
- Apc by schneider electric it customer support worldwide
- Warranty
Похожие устройства
-
APC SURT6000 VA 3UИнструкция по эксплуатации -
APC SURT5000 VA 3UИнструкция по эксплуатации -
APC SURT3000 VA 3UИнструкция по эксплуатации -
APC ES 525VA BE525-RSИнструкция по эксплуатации -
APC CS 350VA BK350-EIИнструкция по эксплуатации -
APC Back-UPS BE700G-FR ARИнструкция по эксплуатации -
APC Back-UPS BGE 90M-CA 120VИнструкция по эксплуатации -
APC Back-UPS BK500Инструкция по эксплуатации -
APC Back-UPS BK350Инструкция по эксплуатации -
APC Smart-UPS SUA1000RMI2UИнструкция по эксплуатации -
APC Back-UPS BR1500G-RSИнструкция по эксплуатации -
APC Back-UPS BR900G-RSИнструкция по эксплуатации
Узнайте, как правильно подключить оборудование к источнику бесперебойного питания для защиты от сбоев и перенапряжений. Следуйте рекомендациям для оптимальной работы устройств.