Optimus Drive PDM20-2S1R5 Руководство по эксплуатации онлайн [24/54] 473996

Optimus Drive PDM20-2S1R5 Руководство по эксплуатации онлайн [24/54] 473996
PDM20 Series
- 23 -
Function
code
Description Set range Unit Default
Display
level
Modific
ation
level
Notes
P0.25
Water
shortage
protection
0011 10 1
Onesjudge water
shortage according to
frequency, current
0OFF
1ON
Tensjudge by pressure
0OFF
1ON
By default, pressure
judgment is ON.
P0.26
Water
shortage fault
detection
threshold
0.0
P0.00
bar 0.5 1
It judges water shortage
only when feedback
pressure is smaller than
the set value.
P0.27
Water
shortage
protection
detection
frequency
060.00
Hz 45.00 1
It is valid when
P0.25 =01.
Comparison frequency
of water shortage
judgment. When
running frequency is
larger than this
frequency, it starts to
judge water shortage.
P0.28
Current
percentage of
water shortage
protection
detection
80.0
300.0
% 150.0 1
It is valid only when
P0.25=01.
Percentage of motor
rated current. When
running current is
smaller than this current,
it judges as water
shortage.
P0.29
Water
shortage
protection
detection time
0900.0
s 20.0

Содержание

Похожие устройства

Скачать