1 ■English
Safety Precautions
• The precautions described herein are classified as WARNING and CAUTION. They both contain important informa-
tion regarding safety. Be sure to observe all precautions without fail.
• Meaning of WARNING and CAUTION notices
WARNING .... Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION .....Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
• The safety marks shown in this manual have the following meanings:
• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
• Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal con-
nections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks
into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.
• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air,
and use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and
even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pres-
sure in the refrigeration cycle, which may result in equipment damage and even injury.
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.
Imperfect earthing may result in electric shocks.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage and insu-
late piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.
01_EN_3P210724-1F.fm Page 1 Tuesday, October 30, 2012 10:39 AM
Содержание
- Installation manual 1
- Models 1
- Mxs40g2v1b 2mks40g2v1b 2mxs40h2v1b 2mks40h2v1b 2mxs40h3v1b 2mks50g2v1b 2mxs50g2v1b 2mks50h2v1b 2mxs50h2v1b 2mxs50h3v1b 2amx40f2v1b 2amx40g2v1b 2amx40g3v1b 2amx50f2v1b 2amx50g2v1b 2amx50g3v1b 1
- R410a split series 1
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 5
- English 5
- Safety precautions 5
- Warning 5
- Accessories 6
- Caution 6
- English 2 6
- Precautions for selecting the location 6
- Also insulate the connection on the outdoor unit 7
- Caution 7
- Clamping material 7
- English 7
- Indoor outdoor unit installation drawings 7
- Indoor outdoor unitinstallation drawings 7
- Insulation tube 7
- Service lid tape 7
- Use tape or insulating material on all connections to prevent air from getting in between the copper piping and the insulation tube be sure to do this if the outdoor unit is installed above 7
- Connections connection port 8
- English 4 8
- How to use reducers 8
- Installation 8
- Precautions on installation 8
- English 9
- If the outdoor unit is positioned higher than the indoor units if the outdoor unit is positioned otherwise if lower than one or more indoor units 9
- Outdoor unit installation guideline 9
- Piping to each indoor unit 20m max 9
- Selecting a location for installation of the indoor units 9
- Selecting a location for installation ofthe indoor units 9
- The maximum allowable length of refrigerant piping and the maximum allowable height difference between the outdoor and indoor units are listed below the shorter the refrigerant piping the better the performance connect so that the piping is as short as possible shortest allow able length per room is 3m 9
- Total length of piping between all units 30m max 9
- Wall facing one side 9
- Walls facing three sides 9
- Walls facing two sides 9
- Where a wall or other obstacle is in the path of outdoor unit s inlet or outlet airflow follow the installation guidelines below for any of the below installation patterns the wall height on the exhaust side should be 1200mm or less 9
- Caution 10
- Drain work only heat pump models 10
- Installing outdoor unit 10
- Refrigerant piping 10
- Refrigerant piping work 10
- Purging air and checking gas leakage 11
- Refrigerant piping work 11
- Warning 11
- Caution 12
- Charging with refrigerant 12
- Important information regarding the refrigerant used 12
- Refilling the refrigerant 12
- English 13
- Precautions for laying refrigerant piping 13
- Refrigerant piping work 13
- Warning 13
- Caution 14
- Forced cooling operation 14
- Pump down operation 14
- Caution 15
- English 15
- Good wrong good wrong 15
- Warning 15
- Wiring 15
- Caution 16
- English 12 16
- Maximum power input limitation setting 16
- Warning 16
- Caution 17
- Econo mode prohibition setting 17
- English 17
- Warning 17
- English 14 18
- Items to check 18
- Trial operation and testing 18
- P210724 1f m07b062f 19
Похожие устройства
- Daikin 2MXS40H3V1B2 Инструкция по монтажу
- Daikin 2MXS50H2V1B Инструкция по монтажу
- Daikin 2MXS50H3V1B Инструкция по монтажу
- Daikin 2MXS50H2V1B Сервис мануал
- Daikin 2MXS50H3V1B2 Инструкция по монтажу
- Daikin 3MXM40N2V1B Руководство по эксплуатации
- Daikin 3MXM40N2V1B Инструкция по монтажу
- Daikin 3MXM40N2V1B Руководство по монтажу
- Daikin 3MXM52N2V1B Руководство по эксплуатации
- Daikin 3MXM52N2V1B Инструкция по монтажу
- Daikin 3MXM52N2V1B Справочное руководство для монтажника
- Daikin 3MXM68N2V1B Руководство по эксплуатации
- Daikin 3MXM40N2V1B Справочное руководство для монтажника
- Daikin 3MXM68N2V1B Инструкция по монтажу
- Daikin 3MXM52N2V1B Руководство по монтажу
- Daikin 3MXM68N2V1B Руководство по монтажу
- Daikin 3MXM68N2V1B Справочное руководство для монтажника
- Daikin 3MXM40N2V1B7 Справочное руководство для монтажника
- Daikin 3MXM40N2V1B7 Инструкция по монтажу
- Daikin 3MXM52N2V1B7 Справочное руководство для монтажника