Daikin 2MXS40H3V1B [6/19] Caution
![Daikin 2MXS40H3V1B [6/19] Caution](/views2/1770001/page6/bg6.png)
■English 2
Accessories
Accessories supplied with the outdoor unit:
Precautions for Selecting the Location
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise, will not cause a nuisance to the
neighbors of the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
Locate the unit so that the noise and the discharged hot air will not annoy the neighbors.
7) Install units, power cords and inter-unit wires at least 3m away from television and radio sets. This is to prevent interfer-
ence to images and sounds. (Noises may be heard even if they are more than 3m away depending on radio wave con-
ditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air condi-
tioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.
NOTE:
Cannot be installed hanging from ceiling or stacked.
CAUTION
When operating the air conditioner in a low outdoor ambient temper-
ature, be sure to follow the instructions described below.
• To prevent exposure to wind, install the outdoor unit with its suc-
tion side facing the wall.
• Never install the outdoor unit at a site where the suction side may
be exposed directly to wind.
• To prevent exposure to wind, it is recommended to install a baffle
plate on the air discharge side of the outdoor unit.
• In heavy snowfall areas, select an installation site where the snow
will not affect the unit.
Installation Manual
There is on the bottom packing case.
1
Refrigerant charge label
There is on the bottom packing case.
1
Drain plug (heat pump models)
There is on the bottom packing case.
1
Multilingual fluorinated greenhouse gases label
There is on the bottom packing case.
1
Screw bag (for fixing the wire retainer)
There is on the bottom packing case.
1
Reducer assembly (only 50 class)
There is on the bottom packing case.
1
A B
C D
E
F
Construct a large canopy.
Construct a pedestal.
Install the unit high enough off the
ground to prevent burying in snow.
01_EN_3P210724-1F.fm Page 2 Tuesday, October 30, 2012 10:39 AM
Содержание
- Installation manual 1
- Models 1
- Mxs40g2v1b 2mks40g2v1b 2mxs40h2v1b 2mks40h2v1b 2mxs40h3v1b 2mks50g2v1b 2mxs50g2v1b 2mks50h2v1b 2mxs50h2v1b 2mxs50h3v1b 2amx40f2v1b 2amx40g2v1b 2amx40g3v1b 2amx50f2v1b 2amx50g2v1b 2amx50g3v1b 1
- R410a split series 1
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 5
- English 5
- Safety precautions 5
- Warning 5
- Accessories 6
- Caution 6
- English 2 6
- Precautions for selecting the location 6
- Also insulate the connection on the outdoor unit 7
- Caution 7
- Clamping material 7
- English 7
- Indoor outdoor unit installation drawings 7
- Indoor outdoor unitinstallation drawings 7
- Insulation tube 7
- Service lid tape 7
- Use tape or insulating material on all connections to prevent air from getting in between the copper piping and the insulation tube be sure to do this if the outdoor unit is installed above 7
- Connections connection port 8
- English 4 8
- How to use reducers 8
- Installation 8
- Precautions on installation 8
- English 9
- If the outdoor unit is positioned higher than the indoor units if the outdoor unit is positioned otherwise if lower than one or more indoor units 9
- Outdoor unit installation guideline 9
- Piping to each indoor unit 20m max 9
- Selecting a location for installation of the indoor units 9
- Selecting a location for installation ofthe indoor units 9
- The maximum allowable length of refrigerant piping and the maximum allowable height difference between the outdoor and indoor units are listed below the shorter the refrigerant piping the better the performance connect so that the piping is as short as possible shortest allow able length per room is 3m 9
- Total length of piping between all units 30m max 9
- Wall facing one side 9
- Walls facing three sides 9
- Walls facing two sides 9
- Where a wall or other obstacle is in the path of outdoor unit s inlet or outlet airflow follow the installation guidelines below for any of the below installation patterns the wall height on the exhaust side should be 1200mm or less 9
- Caution 10
- Drain work only heat pump models 10
- Installing outdoor unit 10
- Refrigerant piping 10
- Refrigerant piping work 10
- Purging air and checking gas leakage 11
- Refrigerant piping work 11
- Warning 11
- Caution 12
- Charging with refrigerant 12
- Important information regarding the refrigerant used 12
- Refilling the refrigerant 12
- English 13
- Precautions for laying refrigerant piping 13
- Refrigerant piping work 13
- Warning 13
- Caution 14
- Forced cooling operation 14
- Pump down operation 14
- Caution 15
- English 15
- Good wrong good wrong 15
- Warning 15
- Wiring 15
- Caution 16
- English 12 16
- Maximum power input limitation setting 16
- Warning 16
- Caution 17
- Econo mode prohibition setting 17
- English 17
- Warning 17
- English 14 18
- Items to check 18
- Trial operation and testing 18
- P210724 1f m07b062f 19
Похожие устройства
- Daikin 2MXS40H3V1B2 Инструкция по монтажу
- Daikin 2MXS50H2V1B Инструкция по монтажу
- Daikin 2MXS50H3V1B Инструкция по монтажу
- Daikin 2MXS50H2V1B Сервис мануал
- Daikin 2MXS50H3V1B2 Инструкция по монтажу
- Daikin 3MXM40N2V1B Руководство по эксплуатации
- Daikin 3MXM40N2V1B Инструкция по монтажу
- Daikin 3MXM40N2V1B Руководство по монтажу
- Daikin 3MXM52N2V1B Руководство по эксплуатации
- Daikin 3MXM52N2V1B Инструкция по монтажу
- Daikin 3MXM52N2V1B Справочное руководство для монтажника
- Daikin 3MXM68N2V1B Руководство по эксплуатации
- Daikin 3MXM40N2V1B Справочное руководство для монтажника
- Daikin 3MXM68N2V1B Инструкция по монтажу
- Daikin 3MXM52N2V1B Руководство по монтажу
- Daikin 3MXM68N2V1B Руководство по монтажу
- Daikin 3MXM68N2V1B Справочное руководство для монтажника
- Daikin 3MXM40N2V1B7 Справочное руководство для монтажника
- Daikin 3MXM40N2V1B7 Инструкция по монтажу
- Daikin 3MXM52N2V1B7 Справочное руководство для монтажника