Daikin FTXS50D2V1W [46/359] Outdoor units heat pump

Daikin FTKS50D2V1W [46/359] Outdoor units heat pump
SiBE12-728 Specifications
Specifications 35
1.4 Outdoor Units - Heat Pump
50Hz 230V
Note:
1. The data are based on the conditions shown in the table below.
Model
5MXS90E7V3B
Cooling Heating
Cooling Capacity kW
Power Consumption W
Running Current A
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC63BXD
Motor Output W 1,920
Refrigerant Oil
Model FVC50K
Charge L 0.75
Refrigerant
Type R-410A
Charge kg 2.99
Air Flow Rates
m³/min
H 57.1 52.5
M 54.5
L 46.0 14.7
cfm
H 2,016 1,854
M 1,924
L 1,624 519
Fan
Type Propeller
Motor Output W 66
Running Current A H: 1.02 / M: 0.97 / L: 0.69 H: 0.90 / L: 0.05
Power Consumption W H: 95 / M: 86 / L: 55 H: 78 / L: 9
Starting Current A 11.8
Dimensions (H×W×D) mm 770×900×320
Packaged Dimensions (H×W×D) mm 900×925×390
Weight kg 73
Gross Weight kg 80
Operation Sound dBA 52 52
Sound Power dBA 66
Piping Connection
Liquid mm
φ
6.4
×
5
Gas mm
φ
9.5
×
2
, φ
12.7
×
1,
φ
15.9
×
2
Drain mm
φ
25.0
Heat Insulation Both Liquid and Gas Pipes
No. of Wiring Connection 3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m 75 (for Total of Each Room)
m 25 (for One Room)
Amount of Additional Charge g/m 20 (30m or more)
Max. Installation Height Difference
m 15 (between Indoor Unit and Outdoor Unit)
m 7.5 (between Indoor Units)
Drawing No. 3D052434#1B
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling Heating Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m

Содержание