Daikin FTXG35EV1BS [10/15] Strip dimension actual size
![Daikin FTXG35EV1BS [10/15] Strip dimension actual size](/views2/1775052/page10/bga.png)
■English 8
6)
Wrap the insulation on the piping with insulating tape. If you are not replacing the drain hose, store it in the location shown below.
NOTE:
1. When fixing the indoor unit screws, use an Indoor unit fixing
screw (M4 × 12L). (In one place on the left side or the right side.)
7) Store any excess power cord behind the indoor unit. (See 4-1. 6))
8) Making sure not to pinch the interunit wiring and the power cord, push
on the bottom of the indoor unit with both hands and attach the tabs.
If the indoor unit won’t attach to the mounting plate, fix the bottom
panel to the mounting plate with screws.
(In one place on the left side or the right side.)
5.
Wiring
1) Strip wire ends (15mm).
2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the
corresponding terminals.
3) Connect the earth wires to the corresponding terminals.
4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
5) Shape the wires so that the service lid fits securely, then close service lid.
WARNING
1) Do not use tapped wires, stand wires, extensioncords, or starbust connections, as they may cause overtheating, electrical
shock,or fire
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the
terminal block.) Doing so may cause electric shock or fire.
Drain hose
FM4
×
12L
F
123
Terminal block
Wiring clamp
Electric parts box
Terminal block
Electric parts box
Wire retainer
Use the specified wire type.
Shape wires so that the
service lid will fit securely.
Secure firmly so that no
external pressure is directly
applied too the terminals.
Use the indicated
wiring and
connect securely.
Firmly secure wire retainer so that
wires sustain no external stress.
1
2
3
123 LN
Safety
breaker
15A
Earth leakage
circuit breaker
Earth
When wire length exceeds
10m, use 2.0mm wires.
H05VV
Firmly fix the wires with
the terminal screws.
Outdoor unit
Indoor
unit
Power
supply
50Hz 220-240V
Firmly fix the wires with
the terminal screws.
15mm12mm
15mm22mm
Strip dimension (actual size)
After shaping
01_EN_3P166464-1.fm Page 8 Saturday, September 17, 2005 11:08 AM
Содержание
- Atxg25ev1b atxg35ev1b atxg50ev1b 1
- Ftxg25ev1bw ftxg25ev1bs ftxg35ev1bw ftxg35ev1bs ctxg50ev1bw ctxg50ev1bs 1
- Installation manual 1
- Models 1
- R410a split series 1
- Daikin industries ltd 2
- Downloaded from www manualslib com manuals search engine 2
- Sb63475 2a 2
- Umeda center bldg 4 12 nakazaki nishi 2 chome kita ku osaka 530 8323 japan 2
- Caution 3
- I english 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing a site 4
- Indoor unit 4
- Wireless remote controller 4
- How to remove and attach the front grill 5
- How to remove and attach the front panel 5
- How to remove and attach the outlet vent panel 5
- Installation tips 5
- How to open the indoor unit service lid 6
- How to set the different addresses 6
- I english 4 6
- Pcb in the indoor unit 6
- Wireless remote controller 6
- Caution 7
- I english 7
- Indoor unit installation drawings 7
- Intelligent eye sensor 7
- Boring a wall hole and installing wall embedded pipe 8
- Indoor unit installation 8
- Installing the mounting plate 8
- Indoor unit installation 9
- Installing interunit wiring 9
- Laying piping hoses and wiring 9
- After shaping 10
- Strip dimension actual size 10
- Warning 10
- Wiring 10
- _en_3p166464 1 fm page 8 saturday september 17 2005 11 08 am 10
- Drain piping 11
- Indoor unit installation 11
- When connecting to an ha system 11
- Coat here with refrigeration machine oil 12
- Flare nut 12
- Flaring the pipe end 12
- Piping union 12
- Refrigerant piping 12
- Refrigerant piping work 12
- Spanner 12
- Torque wrench 12
- _en_3p166464 1 fm page 10 saturday september 17 2005 11 08 am 12
- 2 selection of copper and heat insulation materials 13
- I english 13
- Refrigerant piping work 13
- Trial operation and testing 14
- Trial operation from remote controller 14
- P166464 1 m05b043 15
Похожие устройства
- Daikin CTXG50EV1BW Технические данные
- Daikin CTXG50EV1BW Инструкция по монтажу
- Daikin CTXG50EV1BW Сервис мануал
- Daikin CTXG50EV1BS Технические данные
- Daikin CTXG50EV1BS Инструкция по монтажу
- Daikin CTXG50EV1BS Сервис мануал
- Hotrix QS5 Инструкция по эксплуатации
- Hotrix QS12 Инструкция по эксплуатации
- Hotrix RS3 Инструкция по эксплуатации
- Hotrix RS9 Инструкция по эксплуатации
- Hotrix QS30 Инструкция по эксплуатации
- Hotrix QS24 Инструкция по эксплуатации
- Hotrix RS5 Инструкция по эксплуатации
- Hotrix SWZ9.1500 Инструкция по эксплуатации
- Daikin ATXG25EV1B Инструкция по эксплуатации
- Daikin ATXG25EV1B Инструкция по монтажу
- Daikin ATXG25EV1B Сервис мануал
- Daikin ATXG35EV1B Инструкция по монтажу
- Daikin ATXG35EV1B Инструкция по эксплуатации
- Daikin ATXG35EV1B Сервис мануал