Daikin FTXG35EV1BS [3/15] I english
![Daikin FTXG35EV1BS [3/15] I english](/views2/1775052/page3/bg3.png)
1 ■English
Safety Precautions
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING
...............Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION...............Failure to follow any of CAUTION may in some cases result in grave consequences.
• The following safety symbols are used throughout this manual:
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use and cleaning of the unit
according to the Operation Manual.
Be sure to observe this instruction.
Be sure to establish an earth connection. Never attempt.
WARNING
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the unit’s weight.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable long enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force
on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the shut-off valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the shut-off valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Note for installing the outdoor unit. (For heat pump model only.)
In cold area where the outside air temperature keep below or around freezing-point for a few days, the outdoor unit’s drain may freeze.
If so, it is recommended to install an electric heater in order to protect drain from freezing.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
01_EN_3P166464-1.fm Page 1 Saturday, September 17, 2005 11:08 AM
Содержание
- Atxg25ev1b atxg35ev1b atxg50ev1b 1
- Ftxg25ev1bw ftxg25ev1bs ftxg35ev1bw ftxg35ev1bs ctxg50ev1bw ctxg50ev1bs 1
- Installation manual 1
- Models 1
- R410a split series 1
- Daikin industries ltd 2
- Downloaded from www manualslib com manuals search engine 2
- Sb63475 2a 2
- Umeda center bldg 4 12 nakazaki nishi 2 chome kita ku osaka 530 8323 japan 2
- Caution 3
- I english 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing a site 4
- Indoor unit 4
- Wireless remote controller 4
- How to remove and attach the front grill 5
- How to remove and attach the front panel 5
- How to remove and attach the outlet vent panel 5
- Installation tips 5
- How to open the indoor unit service lid 6
- How to set the different addresses 6
- I english 4 6
- Pcb in the indoor unit 6
- Wireless remote controller 6
- Caution 7
- I english 7
- Indoor unit installation drawings 7
- Intelligent eye sensor 7
- Boring a wall hole and installing wall embedded pipe 8
- Indoor unit installation 8
- Installing the mounting plate 8
- Indoor unit installation 9
- Installing interunit wiring 9
- Laying piping hoses and wiring 9
- After shaping 10
- Strip dimension actual size 10
- Warning 10
- Wiring 10
- _en_3p166464 1 fm page 8 saturday september 17 2005 11 08 am 10
- Drain piping 11
- Indoor unit installation 11
- When connecting to an ha system 11
- Coat here with refrigeration machine oil 12
- Flare nut 12
- Flaring the pipe end 12
- Piping union 12
- Refrigerant piping 12
- Refrigerant piping work 12
- Spanner 12
- Torque wrench 12
- _en_3p166464 1 fm page 10 saturday september 17 2005 11 08 am 12
- 2 selection of copper and heat insulation materials 13
- I english 13
- Refrigerant piping work 13
- Trial operation and testing 14
- Trial operation from remote controller 14
- P166464 1 m05b043 15
Похожие устройства
- Daikin CTXG50EV1BW Технические данные
- Daikin CTXG50EV1BW Инструкция по монтажу
- Daikin CTXG50EV1BW Сервис мануал
- Daikin CTXG50EV1BS Технические данные
- Daikin CTXG50EV1BS Инструкция по монтажу
- Daikin CTXG50EV1BS Сервис мануал
- Hotrix QS5 Инструкция по эксплуатации
- Hotrix QS12 Инструкция по эксплуатации
- Hotrix RS3 Инструкция по эксплуатации
- Hotrix RS9 Инструкция по эксплуатации
- Hotrix QS30 Инструкция по эксплуатации
- Hotrix QS24 Инструкция по эксплуатации
- Hotrix RS5 Инструкция по эксплуатации
- Hotrix SWZ9.1500 Инструкция по эксплуатации
- Daikin ATXG25EV1B Инструкция по эксплуатации
- Daikin ATXG25EV1B Инструкция по монтажу
- Daikin ATXG25EV1B Сервис мануал
- Daikin ATXG35EV1B Инструкция по монтажу
- Daikin ATXG35EV1B Инструкция по эксплуатации
- Daikin ATXG35EV1B Сервис мануал