Tanita BC 418 MA [3/23] Caution
![Tanita BC 418 MA [3/23] Caution](/views2/1078205/page3/bg3.png)
WARNING
• Individuals with a Pacemaker or Other Internal Medical Devices
This equipment sends a weak electrical current through the body during measurement. Individuals
who have internally implanted medical devices, such as Pacemakers, should not use this equipment
due to the risk of malfunction to the device that may be caused by the weak electrical current.
• Inserting and Removing the Power Cord
To reduce the risk of electric shock or product damage, never insert or remove the power cord with
wet hands.
• Do not under any circumstances dismantle or alter the device, as this could result in electric shock or
injury as well as adversely affect the precision of measurements.
• To prevent fire hazard
Use only a correctly wired (100-240VAC) outlet, and do not use a multiple outlet extension cable.
• Measurements for physically disabled persons
Physically disabled persons should not attempt to take measurements alone, but instead should
have their caretakers assist them in using the device.
CAUTION
• Cross Contamination
The Body Composition Analyzer should be used with bare feet. Please be sure to clean the scale
platform with appropriate disinfectant after each use. Never pour any liquid directly on the scale
platform, as it may leak and cause internal damage. Use a soft cloth and appropriate ethyl alcohol
to wipe off platform. Do not wipe the platform with strong chemicals.
• Interpretation of Results
The data provided by this machine, as well as any supplementary information such as diet or
exercise programs based on this data, should be interpreted by a licensed professional.
• Please make sure you place the Weighing Platform on a level and stable surface. If the equipment
is used when the Weighing Platform is unstable because not all feet are on the surface, there may
be a risk of stumbling or inaccurate measurement.
Never jump on the Weighing Platform, there may be a risk of stumbling and malfunction of the
equipment.
• When handling printer unit, avoid any sharp edges.
• For the BC-418; Ensure you use the original AC adapter (MODEL: SA25-0535U). Using an AC
adapter other than the original one may cause malfunction.
Do not insert or remove the plug by the cable.
Maintenance
Since this equipment is accurately manufactured and adjusted, please observe the following instructions.
• Never disassemble the equipment as this may cause malfunction. Users must not disassemble or adjust this equipment.
Please inspect the equipment in accordance with the regulations in your country.
• Unplug the unit from the wall outlet when it will not be in use for long periods of time.
• In order to reduce the risk of a short circuit, please keep any liquid or metal objects (paper clips, etc.) away from the printer.
• Keep the electrodes clean by wiping them with disinfectant.
• Do not drop the unit, and avoid locations with constant vibration.
• Do not put this equipment in direct sunlight, close to heaters or near direct draughts from air conditioners.
• When transferred to any location where there is a difference of more than 20 degrees centigrade (40 degrees Fahrenheit),
wait 2 hours before using.
• When disposing of this unit, please do so in accordance with the prevailing regulations in each country.
General Instructions for Accurate Measurement
This equipment sends out a very weak electric current to measure impedance (electrical resistance) of the body. Therefore, in
principle, users need to use this equipment with bare feet. Moreover, since impedance fluctuates in accordance with the
distribution of body fluid, please observe the following instructions for accurate measurement.
• To prevent a possible discrepancy in measured values, avoid taking measurements after vigorous exercise until sufficiently
rested.
• To prevent inaccurately low body fat percentage measurements and other measurement errors, always hold both arms
straight down when taking measurements.
• As changes in body water and body temperature can have a major impact on measurements, measurements should be
made every day at the same time under similar conditions (always urinating before taking measurements, etc.) to get a
more accurate picture of the measurements over time.
• Ensure that your arms are not touching your side and that the inner thighs are not touching each other during
measurements; if necessary, place a dry towel between your arm and side and/or between your thighs.
• Also, make sure the soles of feet are free of excess dirt, as this may also act as a barrier to the mild current.
• False results may be reported after excessive food /fluid intake, or after periods of intense exercise.
* For further details, see the Technical Notes on page 36.
• This equipment is designed for the majority of the population leading healthy lives with a regular lifestyle. For people
suffering from sickness, or whose lifestyle is very different from the norm, it is recommended that the data from this
product should not be used as an absolute value, but rather as a reference to observe the rate change.
* For further details, see the Technical Notes on page 36.
• Measurement is sometimes impossible on a surface that is strongly vibrating. In this case, please move the equipment onto
a surface with little vibration.
• Do not take measurements while using transmitters, such as mobile phones, which may affect readings.
Safety Notes
54
Caution Symbols
Thank you for purchasing this precision crafted Tanita product. For optimum performance and safety, please familiarize
yourself with the Caution Symbols below. These symbols are designed to alert the user to potential hazards when using this
equipment. Ignoring these Caution Symbols may result in serious injury, or damage to the product.
Please be sure to review before proceeding with the INSTRUCTION MANUAL.
Temperature Range for Use : 0°C / 35°C
Relative Humidity : 30% / 80% (without condensation)
Temperature Range of Environment : -10°C / 50°C
Range of Relative Humidity : 10% / 90% (without condensation)
To avoid malfunctions, avoid storing the equipment where there is direct sunlight, significant temperature
changes, the risk of dampness, a large amount of dust, in the vicinity of fires, or where there is the risk of
receiving vibrations or shocks.
Value Range
100~240VAC
50/60Hz
550mA
Voltage Range
Frequency Range
Electric Current Range
BC-418
Model Name
<Usage Conditions>
<Storage Conditions>
<Power Source>
This symbol indicates the possibility of serious injury if the product is
mishandled or instructions are ignored.
This symbol indicates the possibility of physical injury or equipment
damage if instructions are ignored.
This symbol indicates general precautions that should be taken when using
this product.
WARNING
CAUTION
Содержание
- Body composition analyzer bc 418 1
- Instruction manual 1
- Advantages 2
- Table of contents 2
- Caution 3
- General instructions for accurate measurement 3
- Maintenance 3
- Safety notes 3
- Ac adapter 4
- Accessories 4
- Control box 4
- Digital display 4
- Platform 4
- Please verify that the following components are in the package 4
- Product assembly and components 4
- Product structure 4
- Rear view of control box 4
- Assembly instructions 5
- Digital display 5
- Membrane switch 5
- Caution 6
- Connection and installation 6
- Loading the printer paper roll 6
- Preparation for use 6
- Warning 6
- But natural electric discharge of the rechargeable battery 7
- If no changes are to be made press the key again 7
- If you make an error while inputting a number press the 7
- May occur if the device is not in use for an extended period 7
- Mode selection 7
- More than 2 weeks this will clear the settings making it 7
- Necessary to reset the date and time 7
- Setting date and time 7
- Setting the date and time 7
- Setting the number of printouts the printout language and the printout items 7
- The clock function is backed up by the rechargeable battery 7
- This will return you to the previous input space 7
- Time set 7
- After the input is completed the display will automatically change to the measurement display 8
- Setting the original mode 8
- Athletic 9
- For this printing selection please refer to the page 13 for this goal setter mode please refer to the page 14 9
- Goal setter mode print out 9
- Printing selection 9
- Standard 9
- Target bf 00 9
- The measurement data for each body part the predicted muscle mass the fat mass and the body fat percentage are printed out in this portion 9
- This section calculates the amount of fat that should be lost or gained to achieve the target bf preset by the user and health care professional 9
- This section prints the both the body type and body composition data of the current user 9
- Body composition analysis 10
- Operating instructions 10
- See page 8 for tanita s definition of athlete 10
- Step on 10
- After turning on the unit press the key 11
- Finish measurement 11
- If the printer is on the measurement results will be printed out 11
- Measure the impedance 11
- Measurement after five full cycles the measurement will be complete 11
- Measurement is completed 11
- Select the number of the desired body part on the ten key pad 11
- Taking measurement 11
- The marks will disappear one by one during the 11
- Weight measurement 11
- Weight only function 11
- When measuring is complete press the key to turn off the power 11
- When you continue to measure 11
- With regard to the measurement result please refer to p 22 11
- As reported by gallagher et al at ny obesity research center to determine the percentage of body fat that s appropriate for your body consuit your physician 12
- Based on nih who bmi guidelines 12
- Bmi body mass index is a height to weight ratio and is calculated by the following formula 12
- Bmr basal metabolic rate represents the total energy expended by the body to maintain normal functions at rest such as respiration and circulation 12
- Body fat ranges for standard adults 12
- Explanation of the print out 12
- Fat mass total weight of fat mass in kg lb in the body fat the percentage of total body weight that is fat 12
- Fat to lose gain calculated fat mass to lose or gain to achieve the predicted weight 12
- Ffm fat free mass is comprised of muscle bone tissue water and all other fat free mass in the body 12
- Impedance impedance reflects the bod 12
- Pfm predicted fat mass caluculated fat mass for the given target bf 12
- Pms predicted muscle mass means bone free lean tissue mass ltm 12
- Pw predicted weight calculated weight for the given target bf 12
- S e p 2 0 0 2 1 9 2 9 12
- S inherent resistance to an electrical current muscle acts as a conductor of the electrical current adipose tissue acts as a resistor 12
- Sample 12
- Tbw total body water is the amount of water expressed as lb kg or st lb retained in the body tbw is said to comprise between 50 70 of total body weight generally men tend to have higher water weight than women due to a greater amount of muscle 12
- Weight kg height m2 desirable range 18 24 12
- Caution 13
- Clearing paper jams 13
- Components of the printer unit 13
- Caution 14
- R x d 3 t x d 4 5 g nd 14
- R x d t x d 14
- Rs 232c interface instructions 14
- Troubleshooting 14
- Caution 15
- Output data format 15
- Output data items 15
- Transmission data 15
- Control commands 16
- Error codes 16
- Output fat monitor mode format 16
- Press 0 8 16
- Press to confirm 16
- Push the key 16
- Remote mode 16
- Switch remote mode on and off by pressing 1 or 0 16
- Switching to remote mode 16
- When the unit is switched off press the and keys simultaneously 16
- Choose the units of measurement 17
- Confirm settings 17
- Example of use 17
- Set age 17
- Set body type 17
- Set gender 17
- Set height 17
- Set tare weight 17
- Set target bf 17
- Switch on body composition analyzer 17
- Cancel 18
- Cancel measurement 18
- During measurement 18
- Measurement finished 18
- Reset settings 18
- Resetting 18
- Start measurement 18
- Body impedance measurement methods 19
- Introduction 19
- Principles of body composition measurement via 8 electrode bia 19
- Reliability of body composition analysis via 8 electrode bia 19
- Reliability of body composition measurements with an 8 electrode bia 19
- Technical notes 19
- Causes of errors in impedance measurements 20
- Intra day fluctuations cyclic activity within a single day 20
- 0 0 1 8 0 0 1 6 0 0 1 4 0 0 1 2 0 0 21
- 1 0 0 0 1 8 0 0 1 6 0 0 1 4 0 0 1 2 0 0 21
- Ffm vs r e e 21
- Inter day changes 21
- The applicability of the bmr regression formula and its differences with the old formula 21
- The new regression formula for basal metabolic rate bmr 21
- Weig ht vs r e e 21
- As shown in figure 1 the ree bmr has a stronger relationship to the ffm than to body weight and a difference is visible between males and females in the distribution trends we see that in principle that we should calculate from the ffm rather than by the old formula centered on the relationship with weight 22
- Comparison of bmr values from the tanita multiple regression model and breath analysis presented at nutrition week held in san diego in 2002 22
- Note this model has been calibrated for those between ages of 18 84 those individuals outside of this age range may not be obtain accurate readings 22
- Product specifications 22
- The current bmr retrogression formula is a formula which acts on the principle of using the ffm value from the results of body composition measurement according to the bia a good relationship is shown in the bmr value based on actual breath analysis ree or r 0 p 0 001 these results were presented at the first annual nutrition week american college of nutrition american society for clinical nutrition american society for parenteral and enteral nutrition north american association for the study of obesity held in 2002 in san diego 22
- 2 1 chome maeno cho itabashi ku tokyo japan tel 03 3968 2123 03 3968 7048 fax 03 3967 3766 23
- Dresdener strasse 25 d 71065 sindelfingen germany tel 07031 6189 6 fax 07031 6189 71 23
- This device features radio interference suppression in compliance with valid ec regulation 89 336 eec 23
- Unit 301 303 3 f wing on plaza 62 mody road tsimshatsui east kowloon hong kong tel 852 2838 7111 fax 852 2838 8667 23
Похожие устройства
- Sony VPC-F23Z1R/BI Black Инструкция по эксплуатации
- Tanita CJ-688 Инструкция по эксплуатации
- Fagor 6CF-56GSB Инструкция по эксплуатации
- Tanita HC-207 Инструкция по эксплуатации
- Asus Padfone + Padfone Station Инструкция по эксплуатации
- Fagor 6CF-56VDMB Инструкция по эксплуатации
- Microlife ST 71 Инструкция по эксплуатации
- Rapoo T6 Touch Black Инструкция по эксплуатации
- Sinbo SSW 101 Инструкция по эксплуатации
- Microlife ST 72 Инструкция по эксплуатации
- Rapoo T6 Touch White Инструкция по эксплуатации
- Telefunken TLF FP 500 Инструкция по эксплуатации
- Microlife ST 77 Инструкция по эксплуатации
- Logitech M525 Black Инструкция по эксплуатации
- Telefunken TLF FP 1000 Инструкция по эксплуатации
- Microlife IR 1DE1 Инструкция по эксплуатации
- Logitech M525 Pearl White Инструкция по эксплуатации
- Telefunken TLF CO 501 Инструкция по эксплуатации
- Microsoft ARC Touch Cement Gray USB Инструкция по эксплуатации
- Microlife MT 1951 Инструкция по эксплуатации
Скачать
Случайные обсуждения