Daikin RK25JVE9 [135/162] Removal of propeller fan and fan motor

Daikin RK35JVET9 [135/162] Removal of propeller fan and fan motor
For RK25J, RK35J, RX25J, RX35J Si04-115
126 Removal Procedure
2.4 Removal of Propeller Fan and Fan Motor
Procedure Warning Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Step Procedure Points
"
Disconnect the fan motor
connector S70.
"
Remove the external plates
and the drip proof cover
protecting the electric parts.
"
Be sure to avoid forgetting to
restore the shelter and to
avoid loosing or damaging it.
"
When restoring, match the
"
mark of the propeller fan with
the D-cut of the motor shaft.
"
The fan should be restored
so that the mark
!
will be at
upper part of the fan motor.
1
Release the lead-wires
of the fan motor from
the groove of the switch
box.
2
The propeller fan can
be removed when the
washer faced nut (M8)
is removed.
3
Remove two screws for
removing the fan motor.
The lead wires are
disengaged by raising
the hooks which fix the
lead wires.