Daikin FLY40GAV1NB [11/19] Powerful operation
Содержание
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Z note 2
- A caution 3
- A warning 3
- Caution 3
- Fsafety precautions 3
- Warning 3
- Caution 4
- Installation 4
- Warning 4
- Before opening the front grille be sure to stop the 6
- Caution 6
- Indoor unit 6
- Operation and turn the breaker off 6
- R names of parts 6
- Receiver explanation 6
- C1swini 7
- Names of parts 7
- Outdoor unit 7
- Remote controller 7
- Holder on the wall 8
- Operating the remote controller 8
- Preparation before operation 8
- Remote controller 8
- Setting the batteries 8
- To fix the remote controller 8
- X attention 8
- Attach an air purifying filter 9
- Be careful not to cool the room too much 9
- Blocking sunlight and draft from outdoors increases the cooling effect 9
- Clogged air filters cause inefficient operation and waste 9
- Cover windows with a blind or a curtain 9
- Electricity even while it is not operating 9
- Energy cleaning lamp tells you when the air filters need cleaning clean them once in about every two weeks 9
- For cooling 26 c 28 c for heating 20 c 24 c 9
- Hold the grille by the tabs on the two sides and 9
- If you are not going to use the air conditioner for a long 9
- Indicated by 9
- Indoor unit 9
- Keeping the temperature setting at a moderate level helps save energy 9
- May result in troubles as dust will accumulate inside the indoor unit 9
- Of each air filter then pull it up 9
- Operation without air filters 9
- Period for example in spring or autumn turn the breaker 9
- Preparation before operation 9
- Pull it until it stops 9
- Push the grille at the 5 points 9
- Push the tab at the center 9
- Stable stool and watch your steps carefully in case of ceiling type 9
- The air conditioner always consumes 15 35 watts of 9
- To each air filter 9
- Use the air conditioner in the following conditions 9
- When opening the front grille use a robust and 9
- Dry cool heat fan operation 10
- Adjusting the air flow direction 11
- Adjusting the horizontal blade flap 11
- Adjusting the louvre 11
- Powerful operation 11
- Z attention 11
- Z note 11
- Frimer operation 12
- O rrnn i 12
- Jfcare and cleaning 13
- Before a long idle 14
- Fcare and cleaning 14
- X disposal requirements 14
- Case explanation 15
- These cases are not troubles 15
- Trouble shooting 15
- Case check 16
- Check again 16
- Trouble shooting 16
- Trouble shooting 17
- Fault diagnosis 18
- Trouble shooting 18
- Daikin europe mv 19
- Daikin industries ltd 19
- English 3po6263o 1c m00b044a 19
Похожие устройства
- Daikin FLY40GAV1NB Инструкция по монтажу
- Daikin FLY45GAV1NB Технические данные
- Daikin FLY45GAV1NB Инструкция по монтажу
- Daikin FLY45GAV1NB Инструкция по эксплуатации
- Daikin FLY22GV1NB Инструкция по монтажу
- Daikin FLY22GV1NB Инструкция по эксплуатации
- Daikin FLY22GV1NB Сервис мануал
- Daikin FLY35GV1NB Инструкция по монтажу
- Daikin FLY35GV1NB Инструкция по эксплуатации
- Daikin FLY35GV1NB Сервис мануал
- Daikin FLY40GV1NB Инструкция по монтажу
- Daikin FLY40GV1NB Инструкция по эксплуатации
- Daikin FLY40GV1NB Сервис мануал
- Daikin FLY45GV1NB Инструкция по монтажу
- Daikin FLY45GV1NB Инструкция по эксплуатации
- Daikin FLY45GV1NB Сервис мануал
- Daikin FL25GV1NB Инструкция по монтажу
- Daikin FL25GV1NB Инструкция по эксплуатации
- Daikin FL25GV1NB Сервис мануал
- Daikin FL35GV1NB Инструкция по монтажу
Adjusting the Air Flow Direction POWERFUL Operation You can adjust the air flow direction to increase your comfort POWERFUL operation quickly maximizes the cooling and heating effect in any operation mode Vbu can get the maximum capacity with a touch of a button Adjusting the horizontal blade flap Pressing the POWERFUL button during operation starts POWERFUL operation Press qSWING POWERFUL operation ends in 20 minutes Then the system automatically operates again with the settings which were used before POWERFUL operation Every time the button is pressed Q appears or disappears The flap automatically 1 Press swings up and down POWERFUL To stop the flap at an_____________ angle you like press Ç4SWING No display DRY COOL CNotes on flap angles To cancel POWERFUL operation POWERFUL When SWING is selected the Press flap swinging range depends on the operation mode See the figure z NOTE Unless SWING is selected you should set the flap at a downward position in HEAT mode and at a near horizontal angle in COOL or DRY mode to obtain the best performance In DRY mode if the flap is fixed at a upward position the flap automatically moves in about 60 minutes to prevent condensation on it Z ATTENTION Always use a remote controller to adjust the flap angle If you attempt to move it forcibly with hand when it is swinging the mechanism may be broken Adjusting the louvre When adjusting the louvre use a robust and stable stool and watch your steps carefully In case of ceiling type Hold the knob and move the louvre Obu will find a knob on the left side and the right side blades 10 CNotes on POWERFUL operation In COOL and HEAT mode To maximize the cooling and heating effect the capacity of outdoor unit must be Increased and the air flow rate be fixed to the maximum setting The temperature and air flow settings are not variable In DRY mode The temperature setting is lowered by 3 C and the air flow rate is slightly increased In FAN mode The air flow rate is fixed to the maximum setting