Daikin FLY40GAV1NB [9/19] Preparation before operation

Содержание

Preparation Before Operation Indoor unit Setting the clock Setting the air purifying filters 1 Press When opening the front grille use a robust and stable stool and watch your steps carefully In case of ceiling type AM 0 2 uu is displayed Open the front grille AM Hold the grille by the tabs on the two sides and pull it until it stops blinks 2 Press to set the clock to the TIMER present time 2 PM J J LI Holding down or button rapidly increases or decreases the time Pull out the air filters Push the tab at the center of each air filter then pull it up 3 Set the air purifying filters display Attach an air purifying filter to each air filter 3 Press 4 Set the air filters in their original positions and close the front grille 03 blinks PM J UN Push the grille at the 5 points indicated by Operation without air filters may result in troubles as dust will accumulate inside the indoor unit Now the clock is set NOTE Tips for saving energy Be careful not to cool the room too much Keeping the temperature setting at a moderate level helps save energy Recommended temperature setting For cooling 26 C 28 C For heating 20 C 24 C Cover windows with a blind or a curtain Blocking sunlight and draft from outdoors increases the cooling effect Clogged air filters cause inefficient operation and waste energy Cleaning lamp tells you when the air Filters need cleaning Clean them once in about every two weeks Please note The air conditioner always consumes 15 35 watts of electricity even while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker I OFF o Use the air conditioner in the following conditions Mode COOL Operating conditions If operation is continued out of this range A safety device may work to slop the operation In mull system it may Outdoor lemperatire 1 work io slop tie opration of M Indoor temperature 18to32 C outdoor uni only Indoor iMiKly 80 mx Conderaaion my tr on la nd iri I and dip HEAT Outdoor temperature 10 to 21 C A safety device may work to stop the operation Indoor tempentue Hto2TC DRY A safety device may work to Outdoor temperature 1 stop the operation Indoor temperakn 8lo3 C Condensation may occur on Indoor huritMy 80 mex the Indoor unit and drip 1 combined with REY RE MAE outdoor 20 to 43 C combined with MA outdoor 20 to46 C combined with R outdoor 10 to46 C combined with MEY outdoor 5 to43 C combined with RY MY outdoor 5 to46 C Operation outside this humidity or temperature range may cause a safety device to disable the system

Скачать