Daikin FLY40GAV1NB [4/19] Installation
Содержание
- Operation manual 1
- Contents 2
- Operation 2
- Read before operation 2
- Trouble shooting 2
- Z note 2
- A caution 3
- A warning 3
- Caution 3
- Fsafety precautions 3
- Warning 3
- Caution 4
- Installation 4
- Warning 4
- Before opening the front grille be sure to stop the 6
- Caution 6
- Indoor unit 6
- Operation and turn the breaker off 6
- R names of parts 6
- Receiver explanation 6
- C1swini 7
- Names of parts 7
- Outdoor unit 7
- Remote controller 7
- Holder on the wall 8
- Operating the remote controller 8
- Preparation before operation 8
- Remote controller 8
- Setting the batteries 8
- To fix the remote controller 8
- X attention 8
- Attach an air purifying filter 9
- Be careful not to cool the room too much 9
- Blocking sunlight and draft from outdoors increases the cooling effect 9
- Clogged air filters cause inefficient operation and waste 9
- Cover windows with a blind or a curtain 9
- Electricity even while it is not operating 9
- Energy cleaning lamp tells you when the air filters need cleaning clean them once in about every two weeks 9
- For cooling 26 c 28 c for heating 20 c 24 c 9
- Hold the grille by the tabs on the two sides and 9
- If you are not going to use the air conditioner for a long 9
- Indicated by 9
- Indoor unit 9
- Keeping the temperature setting at a moderate level helps save energy 9
- May result in troubles as dust will accumulate inside the indoor unit 9
- Of each air filter then pull it up 9
- Operation without air filters 9
- Period for example in spring or autumn turn the breaker 9
- Preparation before operation 9
- Pull it until it stops 9
- Push the grille at the 5 points 9
- Push the tab at the center 9
- Stable stool and watch your steps carefully in case of ceiling type 9
- The air conditioner always consumes 15 35 watts of 9
- To each air filter 9
- Use the air conditioner in the following conditions 9
- When opening the front grille use a robust and 9
- Dry cool heat fan operation 10
- Adjusting the air flow direction 11
- Adjusting the horizontal blade flap 11
- Adjusting the louvre 11
- Powerful operation 11
- Z attention 11
- Z note 11
- Frimer operation 12
- O rrnn i 12
- Jfcare and cleaning 13
- Before a long idle 14
- Fcare and cleaning 14
- X disposal requirements 14
- Case explanation 15
- These cases are not troubles 15
- Trouble shooting 15
- Case check 16
- Check again 16
- Trouble shooting 16
- Trouble shooting 17
- Fault diagnosis 18
- Trouble shooting 18
- Daikin europe mv 19
- Daikin industries ltd 19
- English 3po6263o 1c m00b044a 19
Похожие устройства
- Daikin FLY40GAV1NB Инструкция по монтажу
- Daikin FLY45GAV1NB Технические данные
- Daikin FLY45GAV1NB Инструкция по монтажу
- Daikin FLY45GAV1NB Инструкция по эксплуатации
- Daikin FLY22GV1NB Инструкция по монтажу
- Daikin FLY22GV1NB Инструкция по эксплуатации
- Daikin FLY22GV1NB Сервис мануал
- Daikin FLY35GV1NB Инструкция по монтажу
- Daikin FLY35GV1NB Инструкция по эксплуатации
- Daikin FLY35GV1NB Сервис мануал
- Daikin FLY40GV1NB Инструкция по монтажу
- Daikin FLY40GV1NB Инструкция по эксплуатации
- Daikin FLY40GV1NB Сервис мануал
- Daikin FLY45GV1NB Инструкция по монтажу
- Daikin FLY45GV1NB Инструкция по эксплуатации
- Daikin FLY45GV1NB Сервис мануал
- Daikin FL25GV1NB Инструкция по монтажу
- Daikin FL25GV1NB Инструкция по эксплуатации
- Daikin FL25GV1NB Сервис мануал
- Daikin FL35GV1NB Инструкция по монтажу
Do not place under the indoor or outdoor unit anything which must be kept away from moisture Indoor unit moisture in the air may condense and drip in certain conditions outdoor during cooling operation condensation may drip from the piping connections Do not wash the unit with water It may cause an electric shock Do not place a burning appliance in places exposed to the air flow from the unit or under the indoor unit It may cause incomplete combustion or deformation of the unit from heat Do not place a vessel containing water on the unit Water may penetrate into the unit and degrade electrical insulations resulting in an electric shock Do not expose plants or animals directly to the air flow It may cause adverse effects on the plant or the animal Do not block air inlets nor outlets Impaired air flow may result in insufficient performance or troubles Do not allow children to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury Installation WARNING Do not attempt to install the air conditioner by yourself Consult the service shop or a qualified technician Incorrect work will result in water leakage electric shocks or fire For installation consult the service shop where you bought the unit or a qualified technician The air conditioner must be earthed Incomplete earthing may result in electric shocks Do not connect the earth line to a gas pipe water pipe lightening rod or a telephone earth line CAUTION Depending on the environment an earth leakage breaker must be installed Lack of an earth leakage breaker may result in electric shocks Do not install the air conditioner in places where flammable gas may leak If leaked gas should accumulate near the unit fire may occur Arrange the drain hose to ensure smooth drainage Incomplete drainage may cause wetting of the building furniture etc Do not connect the air conditioner to a power supply different from the specification It may cause trouble or fire 3