Daikin FLY40GAV1NB [18/19] Trouble shooting

Содержание

Trouble Shooting Fault diagnosis NOTE I This fault diagnosis is also sticked at the inside of the front panel and can be used by your I DAIKIN service man Fault diagnosis by remote controller In the event of an abnormality the relevant abnormality code appears flashing in the remote controller s temperature display FLY SYSTEM INDOOR UNIT CODE MEANING NORMAL 00 INCORRECT INTERUNIT WIRING INTERUNIT U4 INDOOR PCS DEFECTIVENESS A1 CODE E3 E5 H3 STOPPED BY HIGH PRESSURE CONTROL OR OUTDOOR UNT FREEZE UP PROTECTOR AS FAN MOTOR FAULT C4ORC5 FAULTY HEAT EXCHANGER SENSOR FAULTY SUCTION AIR TEMPERATURE SENSOR C9 AS H9 J6 P3 MEANING HIGH PRESSURE SWITCH ABNORMALITY OL STARTED HIGH PRESSURE SWITCH DEFECT FAULTY SUCTION AIR TEMPERATURE SENSOR FAULTY HEAT EXCHANGER SENSOR ELECTRIC COMPONENTS BOX TEMPERATURE THERMISTOR RELATED ABNORMALITY FL CODE 00 SYSTEM UF OUTDOOR UNIT E0 CODE A1 MEANING NORMAL INCORRECT INTERUNIT WIRING PROTECTORS WORKED INDOOR UNIT AS A6 C4ORC5 C9 MEANING INDOOR PCB DEFECTIVENESS FREEZE UP PROTECTOR FAN MOTOR FAULT FAULTY HEAT EXCHANGER SENSOR FAULTY SUCTION AIR TEMPERATURE SENSOR 17