Daikin CDK35AZVMB [31/62] Limitations for installation for double twin always connect indoor types of the same capacity class installation for twin triple or double twin install all the indoors of 1 s...

Daikin 3MX52AZVMB [31/62] Limitations for installation for double twin always connect indoor types of the same capacity class installation for twin triple or double twin install all the indoors of 1 system in 1 temperature zone do not select fhyb as base unit with mixed use of units swing flap function does not exist on fhyb
30
FTXD25KZV1B
FTX25AZVMB
FTXD35KZV1B
FTX35AZVMB
FTX50AZVMB
FTX60AZVMB
FTX71AZVMB
CDX25AZVMB
CDX35AZVMB
CDX50AZVMB
CDX60AZVMB
FLX25AZVMB
FLX35AZVMB
FLX50AZVMB
FLX60AZVMB
FVX25KZV1B
FVX25AZVMB
FVX35KZV1B
FVX35AZVMB
FVX50AZVMB
RXD25KZV1B
RXD35KZV1B
RX50AZVMB
RX60AZVMB
RX71AZVMB
3MX52AZVMB
4MX68AZVMB
4MX80AZVMB
R-410A,
INVERTER CONTROLLED
HEAT PUMP
P P
P P
P P P
P
P
M M M M M M M M M M M M
M M M M M M M M M M M M M M M
M M M M M M M M M M M M M M M M
Twin - Triple and Double Twin combination -
capacity combinations that are allowed
71 100 125 200 250
valid for sky air 35 + 35 35 + 71 60 + 60 100 + 100 125 + 125
indoor F-series 45 + 60 45 + 71 125 + 71 125 + 60 + 60
and indoor 45 + 45 45 + 45 + 45 45 + 71 + 71 100 + 100 + 45
B-series 35 + 35 + 35 45 + 45 + 100 60 + 60 + 60 + 60
60 + 60 + 60
71 + 71 + 71
45 + 45 + 45 + 45
only valid for 45 + 35 + 35 35 + 71 + 100 125 + 45 + 71
sky air indoor 35 + 35 + 125 100 + 71 + 71
B-series 45 + 60 + 100
71 + 60 +60
for sky air 35 + 35 45 + 45 60 + 60
inverter R-407C
REMARKS
M stands for Multi combination
P stands for Pair combination,
T stands for Twin or Triple or Double Twin combination
(*) "Not yet officially decided for mass production"
(**) The number of connectable FVK(X) models is limited.
2MX52, 3MX68: up to 1 indoor unit. 4MK90, 4MX80: up to 2 indoor units.
Not mentioned about multi system in operation manuals
(***) the “outdoor unit silent operation” will not work, although this button is provided on
the remote controller
(2) means "Scheduled for abolishment"
Limitations for Installation
For Double Twin: always connect indoor types of the same capacity class
Installation for Twin, Triple or Double Twin:
- install all the indoors of 1 system in 1 temperature zone
- do not select FHYB as base unit with mixed use of units (swing flap function does
not exist on FHYB)
Regarding inverter multi combinations
In the combination 3MX68GV1NB with CTX25,35GV1NB(9) there is no auto-restart
and no powerful mode
In the combination 3MX68GV1NB with FTX25,35HV1NB(9), CDX25,35HV1NB only
the indoor unit is working in powerful mode