Daikin CDK35AZVMB [9/62] Specifications

Daikin 4MX80AZVMB [9/62] For control systems and indoor unit accessories see the indoor units
8
ACCESSORIES
Cooling / Heating mode lock (Heat pump models only)
It is now possible to establish cooling or heating mode for 52 to 68 class heat pump models
(already existing for the 80 class) via a switch on the outdoor unit. This is a useful feature for
hotels or offices. Otherwise, the occupant in the “priority room” would determine the cooling
or heating mode of the building — if no “priority room” is set, this can be determined from any
room.
6. Improved durability
The units are constructed in a way to prevent small animals (frogs, mice,...) from reaching
the electrical box.
The PCB is installed upside down in order to improve its anti corrosion characteristics.
A rust proof steel sheet beneath the unit gives additional protection against corrosion.
SPECIFICATIONS
COOLING ONLY
Capacity min.~nom.~max. kW
COP
Sound level *
1
dB(A)
Dimensions HxWxD
Weight kg
Total piping length m
Amount of additional charge g/m
Operation range from~to °CDB
4MK58AZVMB 4MK75AZVMB 4MK90AZVMB
1.4~5.8~6.8 1.4~7.5~8.6 1.9~9.0~9.6
3.50 3.40 3.20
46/43 (39*2) 48/45 (39*2) 48/45 (39*2)
735x936x300 910x900x320
61 69 80
45 60 70
charge less
-10~46
*1 Rated value: the value when using quiet functions
*2 Minimum value (when operating only 1 unit)
SPECIFICATIONS
HEAT PUMP
Capacity cooling
(min.~nom.~max.) heating
COP cooling
heating
Sound level *
1
cooling dB(A)
heating dB(A)
Dimensions HxWxD
Weight kg
Total piping length m
Amount of additional charge g/m
Operation range (from~to) cooling °CDB
heating °CWB
3MX52AZVMB 4MX68AZVMB 4MX80AZVMB
1.4~5.2~6.1 1.4~6.8~7.3 1.9~8.0~ 9.2
1.5~6.8~7.8 1.5~8.6~9.6 2.3~9.6~10.7
3.20 3.20 3.30
3.80 3.70 4.10
46/43 (39*
2
) 48/45 (39*
2
) 48/45 (39*
2
)
47/44 (39*
2
) 49/46 (39*
2
) 49/46 (39*
2
)
735x936x300 908x900x320
61 69 80
45 60 70
20 (20m or more) 20 (30m or more) 20 (40m or more)
-10~46
-15~21
*1 Rated value: the value when using quiet functions
*2 Minimum value (when operating only 1 unit)
ACCESSORIES
5.8~7.5KW CLASS 9.0KW CLASS
KPW-945A4
KKP937A4 KKP945A4
Suction grille
Drain plug
(For control systems and indoor unit accessories : see the indoor units.)
For the outdoor units :