Daikin FTD20JEVLK [12/24] Cooling unit single phase

Daikin FTYD25JEVLK [12/24] Cooling unit single phase
1-10
COMP
ELECTRICAL WIRING CONNECTION
Heat Pump Unit (single phase)
Outdoor Unit
Terminal Block
Indoor Unit
Terminal Block
Power Supply Cable
Cooling Unit (single phase)
Cooling Unit
IMPORTANT : * The À gures shown in the table are for information purpose only. They should be checked and selected
to comply with the local/national codes of regulations. This is also subject to the type of installation and
conductors used.
** The appropriate voltage range should be checked with label data on the unit.
Model
FTYD20JEVLK
RYD20JEVLK
FTYD25JEVLK
RYD25JEVLK
Voltage range**
220V/1Ph/60Hz + !
Power supply cable size* mm
2
Number of conductors
2.5
3
2.5
3
Interconnection cable size* mm
2
Number of conductors
1.0
6
1.0
6
Recommended time delay fuse* A 20 25
Interconnection cable
Outdoor Unit
Terminal Block
Indoor Unit
Terminal Block
Power Supply Cable
Outdoor coil sensor connection wire
(8m long) attached in the indoor unit
Interconnection cable
OF
4WV
COMP
N1
N
L
4WV
COMP
OF
L1
L
N
N1
Model
FTD20JEVLK
RD20JEVLK
FTD25JEVLK
RD25JEVLK
Voltage range**
220V/1Ph/60Hz + !
Power supply cable size* mm
2
Number of conductors
2.5
3
2.5
3
Interconnection cable size* mm
2
Number of conductors
1.0
4
1.0
4
Recommended time delay fuse* A 20 25
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
N1
N
L
COMP
L1
N1
L
N
1 IM-WMJ-0211(0)_DAIKIN (SASO)-E10 10 6/1/11 12:09:53 PM