4 Operation
User reference guide
12
EHVH04~16SU18+26CB6W
Daikin Altherma – Low temperature split
4P449981-1 – 2016.06
▪ At 00:00 the DHWtank is programmed to heat up the water to a
preset value (example: Storage comfort = 60°C).
▪ During the morning, you consume hot water and the DHW tank
temperature decreases.
▪ At 14:00 the DHWtank is programmed to heat up the water to a
preset value (example: Storage eco = 50°C). Hot water is
available again.
▪ During the afternoon and evening, you consume hot water again
and the DHWtank temperature decreases again.
▪ At 00:00 the next day, the cycle repeats.
In scheduled mode, you can do the following:
You can… Location
Read out the active or next scheduled desired
temperature.
DHWtank
temperature
home page
Overrule the active or next scheduled desired
temperature.
Condition:
is displayed on the DHWtank
temperature home page.
Activate the DHWtank booster mode.
Select a DHWtank temperature schedule. Menu structure
Program a DHWtank temperature schedule.
Define preset values that are used by the
DHWtank temperature schedule.
Program a booster heater allowance schedule
to restrict when the booster heater can operate.
Example: Only allow the booster heater to
operate during the night.
(Only for field supplied domestic hot water
pump for secondary return)
Program a domestic hot water pump schedule
to determine when to turn ON and OFF the pump.
When turned ON, the pump runs and makes sure
hot water is instantly available at the tap. To save
energy, only turn ON the pump during periods of
the day when instant hot water is necessary.
See also:
▪ "4.5.5Using the DHWtank temperature home page"on page12
▪ "4.5.6Using the DHWtank booster mode"on page13
▪ "4.7Preset values and schedules"on page16
4.5.4 Scheduled + reheat mode
In scheduled + reheat mode (
), the domestic hot water control is
the same as in scheduled mode. However, when the DHW tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value; example: 35°C), the DHW tank heats up until it
reaches the reheat set point (example: 45°C). This ensures that a
minimum amount of hot water is available at all times.
Example:
t
T
t
60°C
00:00 07:00
50°C
45°C
15°C
14:00 21:00
35°C
1
2
4
5
3
T
t
DHWtank temperature
t Time
60°C Storage comfort
50°C Storage eco
45°C Reheat
35°C Reheat tank temperature–hysteresis value
In scheduled + reheat mode, you can do the following:
You can… Location
Do the same things as in scheduled mode. —
Adjust the preset value (Reheat). Menu structure
See also:
▪ "4.5.3Scheduled mode"on page11
▪ "4.7Preset values and schedules"on page16
4.5.5 Using the DHWtank temperature home
page
Typical DHWtank temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. The examples in the illustrations
below are in DHWtank mode = Scheduled.
User profile = Basic User profile = Detailed
15:20
60°C
Storage comfort
Tank
Mon
15:20
60°C
00:00
Mon
Tue
Tank
Storage comfort
To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)
1 Go to [7.4.3.3]:
> User settings > Preset values > Tank
temperature > Reheat.
Result: You can read out the desired reheat temperature.
2 Press
or to adjust.
To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or scheduled + reheat mode)
1 Go to the DHWtank temperature home page (Tank).
Result:
60°C
is displayed.
t
a
b
T
t
A1
A2 B1 B2 A1A1 A2 B1 B2 A1
T
t
T
t
DHWtank temperature
t Time
Содержание
- User reference guide p.1
- Daikin altherma low temperature split p.1
- Troubleshooting 23 p.2
- Indicates a situation that could result in burning because of extreme hot or cold temperatures p.2
- Topics follow them carefully p.2
- Glossary 24 p.2
- The precautions described in this document cover very important p.2
- General safety precautions 2 p.2
- The original documentation is written in english all other p.2
- General safety precautions p.2
- The installation of the system and all activities described in the p.2
- Energy saving tips 22 p.2
- Table of contents p.2
- Disposal 24 p.2
- Setting the energy prices 21 p.2
- Danger risk of explosion p.2
- Danger risk of electrocution p.2
- Relocation 24 p.2
- Danger risk of burning p.2
- Operation 4 p.2
- Danger p.2
- Meaning of warnings and symbols p.2
- About this document 3 p.2
- Maintenance and service 23 p.2
- About the system 4 p.2
- Languages are translations p.2
- Installation manual and the installer reference guide must be performed by an authorized installer p.2
- About the documentation p.2
- Indicates a situation that results in death or serious injury p.2
- Indicates a situation that could result in explosion p.2
- User reference guide p.2
- Indicates a situation that could result in electrocution p.2
- For the user p.3
- About this document p.3
- The user interface at a glance p.4
- Overview operation p.4
- Operation p.4
- G b c a p.4
- Components in a typical system layout p.4
- Buttons p.4
- About the system p.4
- Using the menu structure p.5
- Using home pages p.5
- Turning on off controls p.5
- Status icons p.5
- Operation p.5
- Basic usage p.5
- To determine which temperature control you are using method 2 p.6
- To determine which temperature control you are using method 1 p.6
- Space heating control p.6
- Setting the space operation mode p.6
- Room thermostat control about room thermostat control p.6
- Operation p.6
- Determining which temperature control you are using p.6
- About space heating control p.6
- Typical room temperature home pages p.7
- To temporarily overrule the room temperature schedule p.7
- To read out the actual and desired room temperature p.7
- To change the mode from scheduled to preset value p.7
- Room thermostat control using the room temperature home page p.7
- Operation p.7
- Example temporarily overruling the schedule and changing the mode to preset value p.7
- Operation p.8
- To set the overrule period p.8
- Operation p.9
- C 47 c p.9
- C 37 c p.9
- To set leaving water temperature preset values main p.10
- To adjust the leaving water temperature main p.10
- To adjust the leaving water temperature additional p.10
- Operation p.10
- Leaving water temperature control using leaving water temperature control not according to a schedule p.10
- Leaving water temperature control using leaving water temperature control according to a schedule p.10
- External room thermostat control using external room thermostat control p.10
- External room thermostat control about external room thermostat control p.10
- Domestic hot water control p.10
- C 47 c p.10
- C 37 c p.10
- About domestic hot water control p.10
- Scheduled mode p.11
- Reheat mode p.11
- Operation p.11
- 00 21 00 p.11
- 00 07 00 p.11
- Operation p.12
- Using the dhw tank booster mode p.13
- Using quiet mode p.13
- Operation p.13
- Advanced usage p.13
- About changing the user permission level p.13
- Using holiday mode p.14
- Operation p.14
- Holiday p.14
- Operation p.15
- Configuring date time units of measurement contrast and backlight p.15
- Reading out information p.15
- Using preset values p.16
- Preset values and schedules p.16
- Operation p.16
- Locking and unlocking buttons and functions p.16
- Configuring user profile and home pages p.16
- Using and programming schedules p.17
- Schedules example p.17
- Operation p.17
- Weather dependent operation p.18
- To set the weather dependent settings p.18
- Predefined schedules room temperature leaving water temperature main p.18
- Predefined schedules leaving water temperature additional p.18
- Predefined schedules dhw tank temperature p.18
- Operation p.18
- Operation p.19
- User reference guide p.20
- P449981 1 2016 6 p.20
- Operation p.20
- Menu structure overview user settings p.20
- Information p.20
- Ehvh04 16su18 26cb6w p.20
- Depending on the selected installer settings settings will be visible invisible p.20
- Daikin altherma low temperature split p.20
- To set the fuel price p.21
- To set the electricity price p.21
- Space heating control p.21
- Setting the energy prices p.21
- Quick wizard p.21
- Installer settings tables to be filled in by installer p.21
- Domestic hot water control a p.21
- Contact helpdesk number 6 p.21
- To set the fuel price in case of an incentive per kwh renewable energy p.22
- To set the electricity price schedule timer p.22
- To set the electricity price in case of an incentive per kwh renewable energy p.22
- Example p.22
- Energy saving tips p.22
- About energy prices in case of an incentive per kwh renewable energy p.22
- Troubleshooting p.23
- To find the contact helpdesk number p.23
- To check the warning history p.23
- To check the error history p.23
- Symptom you are feeling too cold hot in your living room p.23
- Symptom the water at the tap is too cold p.23
- Symptom heat pump failure p.23
- Overview troubleshooting p.23
- Overview maintenance and service p.23
- Maintenance and service p.23
- Relocation p.24
- Overview relocation p.24
- Overview disposal p.24
- Glossary p.24
- Disposal p.24
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Узнайте, как эффективно управлять температурой воды в вашем доме с помощью расписаний и режимов. Обеспечьте комфорт и экономию энергии с помощью простых настроек.