6 Energy saving tips
User reference guide
22
EHVH04~16SU18+26CB6W
Daikin Altherma – Low temperature split
4P449981-1 – 2016.06
3 Press to confirm.
INFORMATION
Price value ranging from 0.00~990 valuta/kWh (with 2
significant values).
INFORMATION
If no schedule is set, the Elec price for High is taken into
account.
5.3 To set the electricity price
schedule timer
1 Go to [7.3.8]: > User settings > Set schedules > Elec price.
2 Program the schedule according to the High, Medium and Low
electricity prices for each time interval.
3 Press to save the schedule.
INFORMATION
The values for High, Medium and Low correspond with the
electricity price values for High, Medium and Low
previously set. If no schedule is set, the electricity price for
High is taken into account.
5.4 About energy prices in case of an
incentive per kWh renewable
energy
An incentive can be taken into account when setting the energy
prices. Although the running cost can increase, the total operation
cost, taking into account the reimbursement will be optimized.
NOTICE
Make sure to modify the setting of the energy prices at the
end of the incentive period.
5.4.1 To set the fuel price in case of an
incentive per kWh renewable energy
Prerequisite: Calculate the value for the fuel price with the following
formula: actual fuel price+(incentive/kWh×0.9)
1 Go to [7.4.6]: > User settings > Preset values > Fuel price.
2 Use and to set the correct price.
3 Press to confirm.
5.4.2 To set the electricity price in case of an
incentive per kWh renewable energy
Prerequisite: Calculate the value for the electricity price with
following formula: actual electricity price+incentive/kWh.
1 Go to [7.4.5]: > User settings > Preset values > Elec price.
2 Use and to set the correct prices for High, Medium and
Low, according to your electricity tariff.
3 Press to confirm.
5.4.3 Example
This is an example and the prices and/or values used in this
example are NOT accurate.
Data Pence/kWh
Fuel price 4.08
Electricity price 12.49
Renewable heat incentive per
kWh
5
Calculation of the fuel price:
Fuel price=Actual fuel price+(incentive/kWh×0.9)
Fuel price=4.08+(5×0.9)
Fuel price=8.58
Calculation of the electricity price:
Electricity price=Actual electricity price+incentive/kWh
Electricity price=12.49+5
Electricity price=17.49
Price Value in breadcrumb
Fuel: 4.08pence/kWh [7.4.6]=8.58
Electricity: 12.49pence/kWh [7.4.5]=17.49
6 Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.
▪ Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
▪ When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
▪ Use a weekly schedule for your normal space heating needs. If
necessary, you can easily deviate from the schedule:
▪ For shorter periods: You can overrule the scheduled room
temperature. Example: When you have a party, or when you
are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode. Example:
When you stay at home during your holiday, or when you go
away during your holiday.
Tips about leaving water temperature
▪ In heating mode, a lower desired leaving water temperature
results in lower energy consumption and better performance.
▪ Set the desired leaving water temperature in accordance with the
heat emitter type. Example: Underfloor heating is designed for
lower leaving water temperature than radiators and heat pump
convectors.
Tips about DHWtank temperature
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode).
▪ Program to heat up the DHW tank to a preset value (Storage
comfort = higher DHW tank temperature) during the night,
because then space heating demand is lower.
▪ If heating up the DHW tank once at night is not sufficient,
program to additionally heat up the DHWtank to a preset value
(Storage eco = lower DHWtank temperature) during the day.
▪ Make sure the desired DHW tank temperature is NOT too high.
Example: After installation, lower the DHWtank temperature daily
by 1°C and check if you still have enough hot water.
▪ Program to turn ON the domestic hot water pump only during
periods of the day when instant hot water is necessary. Example:
In the morning and evening.
Содержание
- User reference guide p.1
- Daikin altherma low temperature split p.1
- Troubleshooting 23 p.2
- Indicates a situation that could result in burning because of extreme hot or cold temperatures p.2
- Topics follow them carefully p.2
- Glossary 24 p.2
- The precautions described in this document cover very important p.2
- General safety precautions 2 p.2
- The original documentation is written in english all other p.2
- General safety precautions p.2
- The installation of the system and all activities described in the p.2
- Energy saving tips 22 p.2
- Table of contents p.2
- Disposal 24 p.2
- Setting the energy prices 21 p.2
- Danger risk of explosion p.2
- Danger risk of electrocution p.2
- Relocation 24 p.2
- Danger risk of burning p.2
- Operation 4 p.2
- Danger p.2
- Meaning of warnings and symbols p.2
- About this document 3 p.2
- Maintenance and service 23 p.2
- About the system 4 p.2
- Languages are translations p.2
- Installation manual and the installer reference guide must be performed by an authorized installer p.2
- About the documentation p.2
- Indicates a situation that results in death or serious injury p.2
- Indicates a situation that could result in explosion p.2
- User reference guide p.2
- Indicates a situation that could result in electrocution p.2
- For the user p.3
- About this document p.3
- The user interface at a glance p.4
- Overview operation p.4
- Operation p.4
- G b c a p.4
- Components in a typical system layout p.4
- Buttons p.4
- About the system p.4
- Using the menu structure p.5
- Using home pages p.5
- Turning on off controls p.5
- Status icons p.5
- Operation p.5
- Basic usage p.5
- To determine which temperature control you are using method 2 p.6
- To determine which temperature control you are using method 1 p.6
- Space heating control p.6
- Setting the space operation mode p.6
- Room thermostat control about room thermostat control p.6
- Operation p.6
- Determining which temperature control you are using p.6
- About space heating control p.6
- Typical room temperature home pages p.7
- To temporarily overrule the room temperature schedule p.7
- To read out the actual and desired room temperature p.7
- To change the mode from scheduled to preset value p.7
- Room thermostat control using the room temperature home page p.7
- Operation p.7
- Example temporarily overruling the schedule and changing the mode to preset value p.7
- Operation p.8
- To set the overrule period p.8
- Operation p.9
- C 47 c p.9
- C 37 c p.9
- To set leaving water temperature preset values main p.10
- To adjust the leaving water temperature main p.10
- To adjust the leaving water temperature additional p.10
- Operation p.10
- Leaving water temperature control using leaving water temperature control not according to a schedule p.10
- Leaving water temperature control using leaving water temperature control according to a schedule p.10
- External room thermostat control using external room thermostat control p.10
- External room thermostat control about external room thermostat control p.10
- Domestic hot water control p.10
- C 47 c p.10
- C 37 c p.10
- About domestic hot water control p.10
- Scheduled mode p.11
- Reheat mode p.11
- Operation p.11
- 00 21 00 p.11
- 00 07 00 p.11
- Operation p.12
- Using the dhw tank booster mode p.13
- Using quiet mode p.13
- Operation p.13
- Advanced usage p.13
- About changing the user permission level p.13
- Using holiday mode p.14
- Operation p.14
- Holiday p.14
- Operation p.15
- Configuring date time units of measurement contrast and backlight p.15
- Reading out information p.15
- Using preset values p.16
- Preset values and schedules p.16
- Operation p.16
- Locking and unlocking buttons and functions p.16
- Configuring user profile and home pages p.16
- Using and programming schedules p.17
- Schedules example p.17
- Operation p.17
- Weather dependent operation p.18
- To set the weather dependent settings p.18
- Predefined schedules room temperature leaving water temperature main p.18
- Predefined schedules leaving water temperature additional p.18
- Predefined schedules dhw tank temperature p.18
- Operation p.18
- Operation p.19
- User reference guide p.20
- P449981 1 2016 6 p.20
- Operation p.20
- Menu structure overview user settings p.20
- Information p.20
- Ehvh04 16su18 26cb6w p.20
- Depending on the selected installer settings settings will be visible invisible p.20
- Daikin altherma low temperature split p.20
- To set the fuel price p.21
- To set the electricity price p.21
- Space heating control p.21
- Setting the energy prices p.21
- Quick wizard p.21
- Installer settings tables to be filled in by installer p.21
- Domestic hot water control a p.21
- Contact helpdesk number 6 p.21
- To set the fuel price in case of an incentive per kwh renewable energy p.22
- To set the electricity price schedule timer p.22
- To set the electricity price in case of an incentive per kwh renewable energy p.22
- Example p.22
- Energy saving tips p.22
- About energy prices in case of an incentive per kwh renewable energy p.22
- Troubleshooting p.23
- To find the contact helpdesk number p.23
- To check the warning history p.23
- To check the error history p.23
- Symptom you are feeling too cold hot in your living room p.23
- Symptom the water at the tap is too cold p.23
- Symptom heat pump failure p.23
- Overview troubleshooting p.23
- Overview maintenance and service p.23
- Maintenance and service p.23
- Relocation p.24
- Overview relocation p.24
- Overview disposal p.24
- Glossary p.24
- Disposal p.24
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Узнайте, как оптимизировать расходы на электроэнергию с помощью простых советов. Настройте тарифы и графики для экономии на отоплении и электроэнергии.