4 Operation
User reference guide
8
EHVH04~16SU18+26CB6W
Daikin Altherma – Low temperature split
4P449981-1 – 2016.06
Settings Description
Schedule 07:00 Comfort You are at home.
Desired temperature =
preset value (Comfort
(heating)).
09:00 Eco You are away.
Desired temperature =
preset value (Eco
(heating)).
17:00 Comfort You are at home.
Desired temperature =
preset value (Comfort
(heating)).
19:00 21°C You are at home and want
it to be a little warmer.
Desired temperature =
custom temperature.
23:00 Eco Desired temperature =
preset value (Eco
(heating)).
Overrule period
(Temperature
lock)
2hours If you temporarily overrule
the schedule by a preset
value, after 2hours the
schedule will be used
again.
If user profile = Basic, then you can temporarily overrule the room
temperature schedule by pressing or .
Situation Description
15:20
18.0°C
15:20
19.0°C
15:20 => Scheduled temperature
= preset value (Eco (heating)) =
18°C.
You temporarily overrule the
schedule.
Desired temperature = custom
temperature = 19°C.
At the next scheduled action
(17:00), the schedule will be
used again.
If user profile = Detailed, then you can:
▪ Temporarily overrule the room temperature schedule by
pressing or (same as if user profile = Basic)
▪ Change the mode from scheduled to a preset value by pressing
or
Situation Description
17:00
18.0°C
15:20
Mon
Scheduled
Room temperature schedule is
used.
15:20 => Desired temperature =
preset value (Eco (heating)) =
18°C.
The next scheduled action is at
17:00 and the desired
temperature will then increase.
Situation Description
17:00
18.0°C
17:00
19.0°C
Mon
Mon
Scheduled
Scheduled
You temporarily overrule the
schedule.
Desired temperature = custom
temperature = 19°C.
At the next scheduled action
(17:00), the schedule will be
used again.
17:00
18.0°C
17:20
20.0°C
Scheduled
Scheduled
Mon
Mon
You change the mode from
scheduled to preset value
(Comfort (heating)).
Desired temperature = preset
value (Comfort (heating)) = 20°C.
After 2hours, the schedule will
be used again (17:20 => 20°C).
17:20
20.0°C
17:20
21.0°C
Scheduled
Scheduled
Mon
Mon
Before you have changed the
mode from scheduled to preset
value, and now you temporarily
overrule the preset value.
Desired temperature = custom
temperature = 21°C.
After 2hours, the schedule will
be used again (17:20 => 20°C).
To set the overrule period
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.2]: > User settings > Temperature lock.
2 Select a value and press :
▪ Permanent
▪ hours (2, 4, 6, 8)
Usage example: You have a party
If you are in the following situation:
▪ You are using the following room temperature schedule:
▪ 17:00 preset value (Comfort) = 20°C
▪ 23:00 preset value (Eco) = 18°C
▪ Tonight you have a party and you want to use the preset value
(Comfort) until 02:00.
Then you can do the following:
1 Set the overrule period (Temperature lock) to 6hours.
2 At 20:00, go to the room temperature home page (Room).
3 Press to select .
Result: The preset value (Comfort) will be used until 02:00.
After that, the schedule will be used again.
Usage example: You go away for a couple of hours
If you are in the following situation:
▪ You are using the following room temperature schedule:
▪ 08:00 preset value (Comfort) = 20°C
▪ 23:00 preset value (Eco) = 18°C
▪ At 14:00, you go away for 3 hours.
Then you can do the following:
1 Set the overrule period (Temperature lock) to 2hours.
2 Go to the room temperature home page (Room).
3 Press to select .
Содержание
- User reference guide p.1
- Daikin altherma low temperature split p.1
- Troubleshooting 23 p.2
- Indicates a situation that could result in burning because of extreme hot or cold temperatures p.2
- Topics follow them carefully p.2
- Glossary 24 p.2
- The precautions described in this document cover very important p.2
- General safety precautions 2 p.2
- The original documentation is written in english all other p.2
- General safety precautions p.2
- The installation of the system and all activities described in the p.2
- Energy saving tips 22 p.2
- Table of contents p.2
- Disposal 24 p.2
- Setting the energy prices 21 p.2
- Danger risk of explosion p.2
- Danger risk of electrocution p.2
- Relocation 24 p.2
- Danger risk of burning p.2
- Operation 4 p.2
- Danger p.2
- Meaning of warnings and symbols p.2
- About this document 3 p.2
- Maintenance and service 23 p.2
- About the system 4 p.2
- Languages are translations p.2
- Installation manual and the installer reference guide must be performed by an authorized installer p.2
- About the documentation p.2
- Indicates a situation that results in death or serious injury p.2
- Indicates a situation that could result in explosion p.2
- User reference guide p.2
- Indicates a situation that could result in electrocution p.2
- For the user p.3
- About this document p.3
- The user interface at a glance p.4
- Overview operation p.4
- Operation p.4
- G b c a p.4
- Components in a typical system layout p.4
- Buttons p.4
- About the system p.4
- Using the menu structure p.5
- Using home pages p.5
- Turning on off controls p.5
- Status icons p.5
- Operation p.5
- Basic usage p.5
- To determine which temperature control you are using method 2 p.6
- To determine which temperature control you are using method 1 p.6
- Space heating control p.6
- Setting the space operation mode p.6
- Room thermostat control about room thermostat control p.6
- Operation p.6
- Determining which temperature control you are using p.6
- About space heating control p.6
- Typical room temperature home pages p.7
- To temporarily overrule the room temperature schedule p.7
- To read out the actual and desired room temperature p.7
- To change the mode from scheduled to preset value p.7
- Room thermostat control using the room temperature home page p.7
- Operation p.7
- Example temporarily overruling the schedule and changing the mode to preset value p.7
- Operation p.8
- To set the overrule period p.8
- Operation p.9
- C 47 c p.9
- C 37 c p.9
- To set leaving water temperature preset values main p.10
- To adjust the leaving water temperature main p.10
- To adjust the leaving water temperature additional p.10
- Operation p.10
- Leaving water temperature control using leaving water temperature control not according to a schedule p.10
- Leaving water temperature control using leaving water temperature control according to a schedule p.10
- External room thermostat control using external room thermostat control p.10
- External room thermostat control about external room thermostat control p.10
- Domestic hot water control p.10
- C 47 c p.10
- C 37 c p.10
- About domestic hot water control p.10
- Scheduled mode p.11
- Reheat mode p.11
- Operation p.11
- 00 21 00 p.11
- 00 07 00 p.11
- Operation p.12
- Using the dhw tank booster mode p.13
- Using quiet mode p.13
- Operation p.13
- Advanced usage p.13
- About changing the user permission level p.13
- Using holiday mode p.14
- Operation p.14
- Holiday p.14
- Operation p.15
- Configuring date time units of measurement contrast and backlight p.15
- Reading out information p.15
- Using preset values p.16
- Preset values and schedules p.16
- Operation p.16
- Locking and unlocking buttons and functions p.16
- Configuring user profile and home pages p.16
- Using and programming schedules p.17
- Schedules example p.17
- Operation p.17
- Weather dependent operation p.18
- To set the weather dependent settings p.18
- Predefined schedules room temperature leaving water temperature main p.18
- Predefined schedules leaving water temperature additional p.18
- Predefined schedules dhw tank temperature p.18
- Operation p.18
- Operation p.19
- User reference guide p.20
- P449981 1 2016 6 p.20
- Operation p.20
- Menu structure overview user settings p.20
- Information p.20
- Ehvh04 16su18 26cb6w p.20
- Depending on the selected installer settings settings will be visible invisible p.20
- Daikin altherma low temperature split p.20
- To set the fuel price p.21
- To set the electricity price p.21
- Space heating control p.21
- Setting the energy prices p.21
- Quick wizard p.21
- Installer settings tables to be filled in by installer p.21
- Domestic hot water control a p.21
- Contact helpdesk number 6 p.21
- To set the fuel price in case of an incentive per kwh renewable energy p.22
- To set the electricity price schedule timer p.22
- To set the electricity price in case of an incentive per kwh renewable energy p.22
- Example p.22
- Energy saving tips p.22
- About energy prices in case of an incentive per kwh renewable energy p.22
- Troubleshooting p.23
- To find the contact helpdesk number p.23
- To check the warning history p.23
- To check the error history p.23
- Symptom you are feeling too cold hot in your living room p.23
- Symptom the water at the tap is too cold p.23
- Symptom heat pump failure p.23
- Overview troubleshooting p.23
- Overview maintenance and service p.23
- Maintenance and service p.23
- Relocation p.24
- Overview relocation p.24
- Overview disposal p.24
- Glossary p.24
- Disposal p.24
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Узнайте, как управлять температурой и расписанием с помощью простых действий. Настройте комфортные условия для вашего дома с помощью удобного интерфейса.