Daikin RHBH11CB [104/112] P383508 1 2015 1 setting is not applicable for this unit

Daikin RHBH11CB [104/112] P383508 1 2015 1 setting is not applicable for this unit
2/9
Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
User settings
└─ Preset values
└─ Room temperature
7.4.1.1 R/W [3-07]~[3-06], step: A.3.2.4
21°C
7.4.1.2 R/W [3-07]~[3-06], step: A.3.2.4
19°C
7.4.1.3 R/W [3-08]~[3-09], step: A.3.2.4
24°C
7.4.1.4 R/W [3-08]~[3-09], step: A.3.2.4
26°C
└─ LWT main
7.4.2.1 [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
7.4.2.2 [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
7.4.2.3 [8-07] R/W [9-03]~[9-02], step: 1°C
18°C
7.4.2.4 [8-08] R/W [9-03]~[9-02], step: 1°C
20°C
7.4.2.5 R/W -10~10°C, step: 1°C
0°C
7.4.2.6 R/W -10~10°C, step: 1°C
-2°C
7.4.2.7 R/W -10~10°C, step: 1°C
0°C
7.4.2.8 R/W -10~10°C, step: 1°C
2°C
└─ Tank temperature
7.4.3.1 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
7.4.3.2 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
7.4.3.3 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
└─ Quiet level
7.4.4 R/W
0: Level 1
1: Level 2
2: Level 3
└─ Electricity price
7.4.5.1 [C-0C]
[D-0C]
R/W 0,00~990/kWh
0/kWh
7.4.5.2 [C-0D]
[D-0D]
R/W 0,00~990/kWh
0/kWh
7.4.5.3 [C-0E]
[D-0E]
R/W 0,00~990/kWh
0/kWh
└─ Fuel price
7.4.6 R/W 0,00~990/kWh
0,00~290/MBtu
8,0/kWh
└─ Set weather dependent
└─ Main
└────────────────── Set weather-dependent heating
7.7.1.1 [1-00] Set weather-dependent heating Low ambient temp. for LWT main zone heating
WD curve.
R/W -40~5°C, step: 1°C
-10°C
7.7.1.1 [1-01] Set weather-dependent heating High ambient temp. for LWT main zone heating
WD curve.
R/W 10~25°C, step: 1°C
15°C
7.7.1.1 [1-02] Set weather-dependent heating Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~[9-00]°C, step: 1°C
35°C
7.7.1.1 [1-03] Set weather-dependent heating Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
R/W [9-01]~min(45, [9-00])°C , step: 1°C
25°C
└────────────────── Set weather-dependent cooling
7.7.1.2 [1-06] Set weather-dependent cooling Low ambient temp. for LWT main zone cooling
WD curve.
R/W 10~25°C, step: 1°C
20°C
7.7.1.2 [1-07] Set weather-dependent cooling High ambient temp. for LWT main zone cooling
WD curve.
R/W
25~43°C, step: 1°C
35°C
7.7.1.2 [1-08] Set weather-dependent cooling Leaving water value for low ambient temp. for
LWT main zone cooling WD curve.
R/W [9-03]~[9-02]°C, step: 1°C
22°C
7.7.1.2 [1-09] Set weather-dependent cooling Leaving water value for high ambient temp. for
LWT main zone cooling WD curve.
R/W [9-03]~[9-02]°C, step: 1°C
18°C
└─ Additional
└────────────────── Set weather-dependent heating
7.7.2.1 [0-00] Set weather-dependent heating Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
R/W [9-05]~min(45,[9-06])°C, step: 1°C
35°C
7.7.2.1 [0-01] Set weather-dependent heating Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
R/W [9-05]~[9-06]°C, step: 1°C
45°C
7.7.2.1 [0-02] Set weather-dependent heating High ambient temp. for LWT add zone heating
WD curve.
R/W 10~25°C, step: 1°C
15°C
7.7.2.1 [0-03] Set weather-dependent heating Low ambient temp. for LWT add zone heating
WD curve.
R/W -40~5°C, step: 1°C
-10°C
└────────────────── Set weather-dependent cooling
7.7.2.2 [0-04] Set weather-dependent cooling Leaving water value for high ambient temp. for
LWT add zone cooling WD curve.
R/W [9-07]~[9-08]°C, step: 1°C
8°C
7.7.2.2 [0-05] Set weather-dependent cooling Leaving water value for low ambient temp. for
LWT add zone cooling WD curve.
R/W [9-07]~[9-08]°C, step: 1°C
12°C
7.7.2.2 [0-06] Set weather-dependent cooling High ambient temp. for LWT add zone cooling
WD curve.
R/W 25~43°C, step: 1°C
35°C
7.7.2.2 [0-07] Set weather-dependent cooling Low ambient temp. for LWT add zone cooling
WD curve.
R/W 10~25°C, step: 1°C
20°C
Installer settings
└─ System layout
└─ Standard
A.2.1.1 [E-00] R/O 0~5
0: LT s
p
lit
A.2.1.2 [E-01] R/O 0: 8
1: 16
A.2.1.3 [E-02] R/O 0: Type 1
1: Type 2
A.2.1.4 [E-03] R/O 0: No BUH
1: 1 step
2: 2 steps
Unit type
Compressor type
Indoor software type
Backup heater steps
Comfort (cooling)
Eco (cooling)
Storage comfort
Storage eco
Reheat
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
Comfort (heating)
Eco (heating)
Field settings table
Installer setting at variance with
default value
High
Medium
Low
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
4P383508-1 - 2015.01 (#) Setting is not applicable for this unit.
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*