1 General safety precautions
Installation and maintenance instructions
5
ROTEX HPSU compact Ultra RHSX(B)-D
Heat pump (indoor unit) with integrated heat accumulator
008.1444444_01 – 11/2018 – EN
This manual provides all the necessary information for installation,
commissioning and maintenance, as well as basic information on op-
eration and settings. Please see the attached documents for a de-
tailed description of operation and control.
All heating parameters needed for smooth operation are already
factory-set. Please refer to other relevant documents for information
on setting the control.
Relevant documents
▪ Indoor unit:
▪ Installation instructions
▪ Commissioning checklist
▪ Heat pump operating manual
▪ RoCon+ HP:
▪ Installation instructions
▪ Operating instructions
▪ Outdoor unit: Installation instructions
▪ Room station RoCon U1 and mixer module RoCon M1: Operating
instructions
▪ Other optional accessories and optional system components: As-
sociated installation and operating instructions
The guides are included in the scope of supply for the individual
devices.
1.1.2 Meaning of warnings and symbols
Warnings in this manual are classified according into their severity
and probability of occurrence.
DANGER
Indicates an immediate danger.
Disregarding this warning can lead to serious injury or
death
WARNING
Indicates a potentially dangerous situation
Disregarding this warning may result in serious physical in-
jury or death.
CAUTION
Indicates a situation which may cause possible damage
Disregarding this warning can cause damage to property
and the environment, and result in minor injuries.
This symbol identifies user tips and particularly useful in-
formation, but not warnings or hazards
Special warning signs
Some types of danger are represented by special symbols.
Electric current
Danger of explosion
Risk of burning or scalding
Risk of poisoning
Validity
Some information in this manual has limited validity. The validity is
highlighted by a symbol.
Heat pump outdoor unit
Heat pump indoor unit
HP convector
Comply with the stipulated tightening torque (see
chap.Chap. 10.4)
Only applies to devices with unpressurised solar system
connection (DrainBack).
Only applies to devices with a bivalent solar system connec-
tion (Biv).
Only applies to indoor units with cooling function
Handling instructions
1 Handling instructions are shown as a list. Actions for which the
sequential order must be maintained are numbered.
è
Results of actions are identified with an arrow.
1.2 Safety instructions for installation
and operation
1.2.1 General
WARNING
Devices that have not been set up and installed correctly
can impair the function of the device and/or cause serious
or fatal injury to the user.
▪ Work on the indoor unit (such as set-up, servicing, con-
nection and initial commissioning) must only be carried
out by persons who are authorised who are authorised
and who have successfully completed qualifying tech-
nical or vocational training, and who have taken part
in advanced training sessions recognised by the relevant
responsible authorities for the specific activity. These in-
clude, in particular, certified heating engineers, quali-
fied electricians and HVAC specialists who, because
of their professional training and expert knowledge,
have experience in the professional installation and
maintenance of heating, cooling and air conditioning
systems as well as hot water storage tanks.
▪ Switch off the external main switch before starting any
work on the indoor unit and secure against being
switched on inadvertently.
▪ Do not leave any tools or other objects below the hood
of the unit after finishing installation or maintenance
work.
Avoiding danger
The indoor unit conforms to the state of the art and meets all recog-
nised technical requirements. However, improper use may result in
serious physical injuries or death, as well as property damage. To
prevent such risks, only install and operate the devices:
▪ as stipulated and in perfect condition,
▪ with an awareness of safety and the hazards involved.
This assumes knowledge and use of the contents of this manual, of
the relevant accident prevention regulations as well as the recog-
nised safety-related and occupational health rules.
Before working on the hydraulic system
▪ Work on the system (such as installation, connection and initial
commissioning, for example) must only be carried out by persons
who are authorised, who have successfully completed qualifying
technical or vocational training for the respective activity and who
have taken part in advanced training sessions recognised by the
relevant responsible authority.
Содержание
- Rotex hpsu compact ultra p.1
- Instructions p.1
- Installation and maintenance p.1
- Faults and malfunctions 40 p.3
- Product description 9 p.3
- Taking out of operation 54 p.3
- Start up 30 p.3
- Set up and installation 12 p.3
- Notes 64 p.3
- List of keywords 67 p.3
- List of contents p.3
- Installation and maintenance instructions p.3
- Inspection and maintenance 36 p.3
- Hydraulic connection 34 p.3
- Handover to operator and warranty 8 p.3
- General safety precautions 4 p.3
- Technical data 57 p.3
- Particular safety instructions p.4
- Observing the instructions p.4
- General safety precautions p.4
- General p.5
- Safety instructions for installation and operation p.5
- Meaning of warnings and symbols p.5
- General safety precautions p.5
- Requirements for the heating water p.6
- Intended use p.6
- General safety precautions p.6
- Electrical installation p.6
- Device installation room p.6
- Operation p.7
- Heating system and sanitary connection p.7
- General safety precautions p.7
- Warranty conditions p.8
- Instruct the owner p.8
- Handover to operator and warranty p.8
- Product description p.9
- Design and components p.9
- Product description p.10
- Product description p.11
- Function of the 3 way switch valves p.11
- Set up and installation p.12
- Dimensions and connection dimensions p.12
- Transport and delivery p.13
- Set up and installation p.13
- Selecting the installation site p.13
- Installing the heat pump p.13
- Set up and installation p.14
- Installing the device p.14
- Set up and installation p.15
- Remove the protective cover p.15
- Remove the front screen p.15
- Preparing the device for installation p.15
- Moving the controller housing to the service position p.15
- Set up and installation p.16
- Removing the bottom thermal insulation p.16
- Open the controller housing p.16
- Set up and installation p.17
- Opening the vent valve p.17
- Aligning the connections of the heating inflow and return flow p.17
- Making the hood opening p.18
- Installing the rotary switch of the controller p.18
- Installing optional accessories p.18
- Installation of the external heat generator connection set p.18
- Installation of the electric backup heater p.18
- Set up and installation p.18
- Water connection p.19
- Set up and installation p.19
- Installation of the p connection kit p.19
- Installation of the db connection kit p.19
- Set up and installation p.20
- Connecting hydraulic lines p.20
- Set up and installation p.21
- Electrical connection p.21
- Connecting the drain p.21
- Set up and installation p.22
- Overall connection diagram p.22
- Position of the printed circuit boards and terminal strips p.23
- Mains connection p.23
- General information on the electrical connection p.23
- Connecting the heat pump outdoor unit p.23
- Set up and installation p.23
- Rtx ehs x1 p.23
- Rocon hp p.23
- Rocon bm2c p.23
- Set up and installation p.24
- External switching contact p.24
- Eba external requirement request p.24
- Connecting the outside temperature sensor optional p.24
- Connecting an external heat generator p.24
- Set up and installation p.25
- Connecting the room thermostat p.25
- Set up and installation p.26
- Connection of optional rocon system components p.26
- Connecting the hp convector p.26
- Off peak mains connection ht nt p.27
- Connecting switching contacts aux outputs p.27
- Set up and installation p.27
- Set up and installation p.28
- Laying refrigerant lines p.28
- Connection for refrigerant p.28
- Connecting an intelligent controller smart grid sg p.28
- Set up and installation p.29
- Pressure test and filling the refrigerant circuit p.29
- Filling the system p.29
- Filling the storage tank p.29
- Filling the heating system p.29
- Filling hot water heat exchangers p.29
- Checking the water quality and adjusting the pressure gauge p.29
- Start up p.30
- Requirements p.30
- Initial commissioning p.30
- Bleeding the hydraulic system p.30
- Starting the unit and start up p.30
- Start up p.31
- Setting the screed program parameter only as required p.31
- Checking the minimum flow p.31
- Start up p.32
- Requirements p.32
- Re commissioning p.32
- Commissioning checklist p.32
- Start up p.33
- Hydraulic system connection p.34
- Hydraulic connection p.34
- Hydraulic connection p.35
- Inspection and maintenance p.36
- General overview of inspection and maintenance p.36
- Inspection and maintenance p.37
- Filling topping up the storage tank p.37
- Inspection and maintenance tasks p.37
- Inspection and maintenance p.38
- Filling topping up the heating system p.38
- Inspection and maintenance p.39
- Troubleshooting p.40
- Overview of possible malfunctions p.40
- Faults and malfunctions p.40
- Faults and malfunctions p.41
- Faults and malfunctions p.42
- Faults and malfunctions p.43
- Fault codes p.43
- Faults and malfunctions p.44
- Faults and malfunctions p.45
- Faults and malfunctions p.46
- Faults and malfunctions p.47
- Faults and malfunctions p.48
- Faults and malfunctions p.49
- Faults and malfunctions p.50
- Faults and malfunctions p.51
- Faults and malfunctions p.52
- Faults and malfunctions p.53
- Emergency operation p.53
- Temporary shutdown p.54
- Taking out of operation p.54
- Draining the storage tank p.54
- Taking out of operation p.55
- Final shutdown and disposal p.55
- Draining the heating circuit and hot water circuit p.55
- Taking out of operation p.56
- Technical data p.57
- Basic data p.57
- Information on the type plate p.58
- Technical data p.58
- Technical data p.59
- Sensor characteristic lines p.59
- Characteristic lines p.59
- Characteristic curves for pumps p.59
- Tightening torque p.60
- Technical data p.60
- Minimum floor area and ventilation openings p.60
- Technical data p.61
- Electrical connection diagram p.62
- Technical data p.63
- List of keywords p.67
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Узнайте о безопасной установке, настройке и обслуживании тепловых насосов. Полезные советы и инструкции для правильной эксплуатации и предотвращения несчастных случаев.