Installation manual
18
EBHQ006+008BBV3
Unit for air to water heat pump system
4P347825-1A – 2013.04
Symptom 5: The water pressure relief valve leaks
Symptom 6: The user interface displays "nn
nn
" when pressing
certain buttons
Symptom 7: Space heating capacity shortage at low outdoor
temperatures
Symptom 8: Temperature values displayed on the remote controller (user
interface) are displayed in °F instead of °C
17.3. Error codes
When a safety device is activated, the user interface LED will be
flashing, and an error code will be displayed.
A list of all errors and corrective actions can be found in the
installation manual of the EKCB indoor manual.
18. DISPOSAL REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with the applicable legislations.
19. UNIT SPECIFICATIONS
Technical specifications
Electrical specifications
(*) European/International Technical Standard setting the limits for harmonic
currents by equipment connected to public low-voltage systems
with input current >16 A and ≤75 A per phase
POSSIBLE CAUSES CORRECTIVE ACTION
Dirt is blocking the water pressure
relief valve outlet.
Check for correct operation of the
pressure relief valve by turning the
red knob on the valve counter
clockwise:
• If you do not hear a clacking sound,
contact your local dealer.
•In case the water keeps running out
of the unit, close both the water inlet
and outlet shut-off valves first and
then contact your local dealer.
POSSIBLE CAUSES CORRECTIVE ACTION
The current permission level is set to
a level that prevents using the
pressed button.
Change the "user permission level"
field setting [0-00], refer to the
chapter "Field settings" in the EKCB
installation manual.
POSSIBLE CAUSES CORRECTIVE ACTION
Backup heater operation is not
activated.
Check that the "backup heater
operation status" field setting [4-00]
is turned on, refer to the chapter
"Field settings" in the EKCB
installation manual.
Check whether or not the thermal
protector of the backup heater has
been activated (refer to "5.2. Main
components of the outdoor unit" on
page 6, "Backup heater thermal
protector" in the installation manual
of the EKMBUH for location of the
reset button).
Check if booster heater and backup
heater are configured to operate
simultaneously (field setting [4-01],
refer to the chapter "Field settings" in
the EKCB installation manual).
Check whether or not the thermal
fuse of the backup heater is blown
(refer to "5.2. Main components of
the outdoor unit" on page 6, "Backup
heater thermal fuse" in the
installation manual of the EKMBUH
for location of the reset button).
The backup heater equilibrium
temperature has not been
configured correctly.
Raise the
'equilibrium temperature'
field setting [5-01] to activate backup
heater operation at a higher outdoor
temperature.
Too much heat pump capacity is
used for heating domestic hot water
(applies only to installations with a
domestic hot water tank).
Check that the
'space heating priority
temperature' field settings are
configured appropriately:
Make sure that the 'space heating
priority status' field setting [5-02] is
enabled.
Raise the 'space heating priority
temperature' field setting [5-03] to
activate booster heater operation at
a higher outdoor temperature.
POSSIBLE CAUSES CORRECTIVE ACTIONS
You accidentally changed the setting
to view the temperature values in °F
by pushing the ib and jb
buttons simultaneously.
To change the display back to °C,
push ib and jb buttons
simultaneously for 5 seconds.
Execute same procedure to change
back to the °F display. The default
temperature display is in °C.
EBHQ006BBV3 EBHQ008BBV3
Nominal capacity
• Cooling
(a)
(a) Only if connected to EKCBX008BCV3
Refer to the Technical Data
• Heating
Refer to the Technical Data
Dimensions H x W x D
(mm)
805 x 1190 x 360
Weight
• Machine weight
(kg)
95
• Operation weight
(kg)
99
Connections
•water inlet/outlet
1" MBSP
(b)
(b) MBSP = Male British Standard Pipe
Field installed waterpiping
•Minimum pressure
resistance
(bar)
4
•Minimim temperature
resistance
(°C)
65
• Recommended diameter
(inch)
1
Refrigerant
•Type
R410A
• Charge
(kg)
1.7
Expansion vessel
•Volume
(l)
6
•Pre-pressure
(bar)
1
• Maximum working pressure
(MWP)
(bar)
3.0
Pump
•Type
water cooled
•No. of speed
3
• Nominal ESP
• Cooling
(a)
(kPa)
49.7 45.8
• Heating
(kPa)
47.2 34.0
Sound level
• Sound power cooling
(a)
(dBA)
63 63
• Sound pressure cooling
(a)
(dBA)
48 50
• Sound power heating
(dBA)
61 62
• Sound pressure heating
(dBA)
48 49
Internal water volume
(l)
5.5
Pressure relief valve
water circuit
(bar)
3
Operation range - water side
• Heating
(°C)
+15~+50
• Cooling
(a)
(°C)
+5~+22
• Domestic hot water by heat
pump
(°C)
+25~+80
Operation range - air side
• Heating
(°C)
–15~+25
• Cooling
(a)
(°C)
+10~+43
• Domestic hot water by heat
pump
(°C)
–15~+35
EBHQ006BBV3 EBHQ008BBV3
Power circuit
• Phase
1~
•Frequency
(Hz)
50
•Voltage
(V)
230 (±10%)
Maximum running current
(a)
(a) Equipment complying with EN/IEC 61000-3-12 (*)
• Cooling
(b)
(b) Only if connected to EKCBX008BCV3
(A)
16.25
• Heating
(A)
18
Содержание
- Installation manual 1
- Unit for air to water heat pump system 1
- Daikin europe n v 2
- Ebhq006bbv3 ekcbh008b v3 ebhq006bbv3 ekcbx008b v3 ebhq008bbv3 ekcbh008b v3 ebhq008bbv3 ekcbx008b v3 2
- En60335 2 40 2
- Jean pierre beuselinck director ostend 2nd of may 2013 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 ec 2
- P350991 1 2
- Installation manual 3
- Ontents 3
- Afety precautions 4
- Efinitions 4
- Meaning of used terms 4
- Meaning of warnings and symbols 4
- Combination and options 6
- Connection to a benefit kwh rate power supply 6
- General information 6
- Heating cooling units and heating only units 6
- Model identification 6
- Ntroduction 6
- Scope of the manual 6
- 2 3 5 4 7
- For access to the terminals following panels have to be removed as shown in the figure below 7
- Opening of the outdoor unit to gain access to the unit the service panels need to be opened as shown in the figure below 7
- Main components of the outdoor unit 8
- Electing an installation location 9
- Functional diagram of outdoor hydraulic compartment 9
- General precautions on outdoor installation location 9
- Main components of the outdoor unit switch box 9
- Place of installation 10
- Selecting an outdoor location in cold climates 10
- Wheater dependent precautions 10
- Dimensions of the outdoor unit 11
- Handling 11
- Handling and unpacking the unit 11
- Imensions and service space 11
- Inspection 11
- Nspectin 11
- Service space of the outdoor unit 11
- Ypical application examples 11
- Checking the water circuit 13
- Checking the water volume and expansion vessel pre pressure 13
- Iping connection work 13
- Connecting the water circuit 14
- Setting the pre pressure of the expansion vessel 14
- Protecting the water circuit against freezing 15
- Charging water 16
- Initial start up at low ambient temperatures 16
- Lectrical wiring work 16
- Mportant information regarding the refrigerant used 16
- Piping insulation 16
- Up and configuration 16
- Water piping freezing prevention 16
- Est run and final check 17
- Final check 17
- Pre run checks 17
- Procedure 17
- Test run operation manual 17
- Underfloor heating screed dry out program 17
- Aintenance and service 18
- Checks 18
- Maintenance activities 18
- Maintenance introduction 18
- Peration of the unit 18
- Service precautions 18
- General guidelines 19
- General symptoms 19
- Roubleshooting 19
- Service mode operation 19
- Electrical specifications 20
- Error codes 20
- Isposal requirements 20
- Nit specifications 20
- Technical specifications 20
Похожие устройства
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Сертификат
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Сертификат
- Foodatlas H001 Инструкция по эксплуатации
- Foodatlas H001 Сертификат
- Foodatlas PS-1 Инструкция по эксплуатации
- Foodatlas PS-1 Сертификат
- Foodatlas SM-1388 Инструкция по эксплуатации
- Foodatlas SM-1388 Сертификат
- Daikin EBLQ05C2V3 Руководство по монтажу
- Daikin EBLQ05C2V3 Общие правила техники безопасности
- Daikin EBLQ05C2V3 Руководство по применению для установщика
- Daikin EBLQ07C2V3 Руководство по монтажу
- Daikin EBLQ07C2V3 Руководство по применению для установщика
- Daikin EBLQ07C2V3 Общие правила техники безопасности
- Foodatlas KCB-1Y Инструкция по эксплуатации
- Foodatlas KCB-1Y Сертификат
- Foodatlas KCB-1F Инструкция по эксплуатации
- Foodatlas KCB-1F Сертификат