Daikin EBHQ008BBV3 [4/24] Afety precautions
![Daikin EBHQ006BBV3 [4/24] Afety precautions](/views2/1788338/page4/bg4.png)
Installation manual
2
EBHQ006+008BBV3
Unit for air to water heat pump system
4P347825-1A – 2013.04
1. DEFINITIONS
1.1. Meaning of warnings and symbols
Warnings in this manual are classified according to their severity and
probability of occurrence.
Some types of danger are represented by special symbols:
1.2. Meaning of used terms
Installation manual:
Instruction manual specified for a certain product or application,
explaining how to install, configure and maintain it.
Operation manual:
Instruction manual specified for a certain product or application,
explaining how to operate it.
Maintenance instructions:
Instruction manual specified for a certain product or application,
which explains (if relevant) how to install, configure, operate and/or
maintain the product or application.
Dealer:
Sales distributor for products as per the subject of this manual.
Installer:
Technical skilled person who is qualified to install products as per the
subject of this manual.
User:
Person who is owner of the product and/or operates the product.
Service company:
Qualified company which can perform or coordinate the required
service to the unit.
Applicable legislation:
All international, European, national and local directives, laws,
regulations and/or codes which are relevant and applicable for a
certain product or domain.
Accessories:
Equipment which is delivered with the unit and which needs to be
installed according to instructions in the documentation.
Optional equipment:
Equipment which can optionally be combined to the products as per
the subject of this manual.
Field supply:
Equipment which needs to be installed according to instructions in
this manual, but which are not supplied by Daikin.
2. GENERAL SAFETY PRECAUTIONS
All activities described in this manual shall be carried out by an
installer.
Be sure to wear adequate personal protection equipment (protection
gloves, safety glasses, …) when performing installation, maintenance
or service to the unit.
If not sure of installation procedures or operation of the unit, always
contact your local dealer for advice and information.
Improper installation or attachment of equipment or accessories
could result in electric shock, short-circuit, leaks, fire or other damage
to the equipment. Be sure only to use accessories and optional
equipment made by Daikin which are specially designed for use with
the products as of subject in this manual and have them installed by
an installer.
The precautions listed here are divided into the following four types.
They all cover very important topics, so be sure to follow them
carefully.
■ Safely dispose of packing materials. Packing materials,
such as nails and other metal or wooden parts, may
cause stabs or other injuries.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.
NOTICE
Indicates situations that may result in equipment or
property-damage accidents only.
INFORMATION
This symbol identifies useful tips or additional information.
Electric current.
Danger of burning and scalding.
DANGER: ELECTRICAL SHOCK
Switch off all power supply before removing the switch box
service panel or before making any connections or
touching electrical parts.
Do not touch any switch with wet fingers. Touching a switch
with wet fingers can cause electrical shock. Before
touching electrical parts, turn off all applicable power
supply.
To avoid electric shock, be sure to disconnect the power
supply 1 minute or more before servicing the electrical
parts. Even after 1 minute, always measure the voltage at
the terminals of main circuit capacitors or electrical parts
and, before touching, be sure that those voltages are
50 V DC or less.
When service panels are removed, live parts can easily be
touched by accident. Never leave the unit unattended
during installation or servicing when the service panel is
removed.
DANGER: DO NOT TOUCH PIPING AND INTERNAL
PARTS
Do not touch the refrigerant piping, water piping or internal
parts during and immediately after operation. The piping
and internal parts may be hot or cold depending on the
working condition of the unit.
Your hand may suffer burns or frostbite if you touch the
piping or internal parts. To avoid injury, give the piping and
internal parts time to return to normal temperature or, if
you must touch them, be sure to wear protective gloves.
WARNING
■ Tear apart and throw away plastic packaging bags so
that children will not play with them.
Children playing with plastic bags face danger of death
by suffocation.
Содержание
- Installation manual 1
- Unit for air to water heat pump system 1
- Daikin europe n v 2
- Ebhq006bbv3 ekcbh008b v3 ebhq006bbv3 ekcbx008b v3 ebhq008bbv3 ekcbh008b v3 ebhq008bbv3 ekcbx008b v3 2
- En60335 2 40 2
- Jean pierre beuselinck director ostend 2nd of may 2013 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 ec 2
- P350991 1 2
- Installation manual 3
- Ontents 3
- Afety precautions 4
- Efinitions 4
- Meaning of used terms 4
- Meaning of warnings and symbols 4
- Combination and options 6
- Connection to a benefit kwh rate power supply 6
- General information 6
- Heating cooling units and heating only units 6
- Model identification 6
- Ntroduction 6
- Scope of the manual 6
- 2 3 5 4 7
- For access to the terminals following panels have to be removed as shown in the figure below 7
- Opening of the outdoor unit to gain access to the unit the service panels need to be opened as shown in the figure below 7
- Main components of the outdoor unit 8
- Electing an installation location 9
- Functional diagram of outdoor hydraulic compartment 9
- General precautions on outdoor installation location 9
- Main components of the outdoor unit switch box 9
- Place of installation 10
- Selecting an outdoor location in cold climates 10
- Wheater dependent precautions 10
- Dimensions of the outdoor unit 11
- Handling 11
- Handling and unpacking the unit 11
- Imensions and service space 11
- Inspection 11
- Nspectin 11
- Service space of the outdoor unit 11
- Ypical application examples 11
- Checking the water circuit 13
- Checking the water volume and expansion vessel pre pressure 13
- Iping connection work 13
- Connecting the water circuit 14
- Setting the pre pressure of the expansion vessel 14
- Protecting the water circuit against freezing 15
- Charging water 16
- Initial start up at low ambient temperatures 16
- Lectrical wiring work 16
- Mportant information regarding the refrigerant used 16
- Piping insulation 16
- Up and configuration 16
- Water piping freezing prevention 16
- Est run and final check 17
- Final check 17
- Pre run checks 17
- Procedure 17
- Test run operation manual 17
- Underfloor heating screed dry out program 17
- Aintenance and service 18
- Checks 18
- Maintenance activities 18
- Maintenance introduction 18
- Peration of the unit 18
- Service precautions 18
- General guidelines 19
- General symptoms 19
- Roubleshooting 19
- Service mode operation 19
- Electrical specifications 20
- Error codes 20
- Isposal requirements 20
- Nit specifications 20
- Technical specifications 20
Похожие устройства
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Сертификат
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Сертификат
- Foodatlas H001 Инструкция по эксплуатации
- Foodatlas H001 Сертификат
- Foodatlas PS-1 Инструкция по эксплуатации
- Foodatlas PS-1 Сертификат
- Foodatlas SM-1388 Инструкция по эксплуатации
- Foodatlas SM-1388 Сертификат
- Daikin EBLQ05C2V3 Руководство по монтажу
- Daikin EBLQ05C2V3 Общие правила техники безопасности
- Daikin EBLQ05C2V3 Руководство по применению для установщика
- Daikin EBLQ07C2V3 Руководство по монтажу
- Daikin EBLQ07C2V3 Руководство по применению для установщика
- Daikin EBLQ07C2V3 Общие правила техники безопасности
- Foodatlas KCB-1Y Инструкция по эксплуатации
- Foodatlas KCB-1Y Сертификат
- Foodatlas KCB-1F Инструкция по эксплуатации
- Foodatlas KCB-1F Сертификат