EBHQ006+008BBV3
Unit for air to water heat pump system
4P347825-1A – 2013.04
Installation manual
3
■ Ask your dealer or qualified personnel to carry out
installation work.
Do not install the machine by yourself.
Improper installation may result in water leakage, electric
shocks or fire.
■ Perform installation work in accordance with this
installation manual.
Improper installation may lead to water leakage, electric
shocks or fire.
■ Be sure to use only the specified accessories and parts
for installation work.
Failure to use the specified parts may result in water
leakage, electric shocks, fire, or the unit falling.
■ Install the unit on a foundation that can withstand its
weight.
■ Insufficient strength may result in the fall of equipment
and causing injury.
■ Carry out the specified installation work in consideration
of strong winds, hurricanes, or earthquakes.
Improper installation work may result in accidents due to
fall of equipment.
■ Make certain that all electrical work is carried out by
qualified personnel according to the applicable
legislations and this installation manual, using a separate
circuit.
Insufficient capacity of the power supply circuit or
improper electrical construction may lead to electric
shocks or fire.
■ Be sure to install an earth leakage circuit breaker in
accordance with the applicable legislations. Failure to do
so may cause electrical shock and fire.
■ Make sure that all wiring is secure, using the specified
wires and ensuring that external forces do not act on the
terminal connections or wires.
Incomplete connection or fixing may cause a fire.
■ When wiring between the indoor and the outdoor units
and wiring the power supply, form the wires so that the
panels can be securely fastened.
If the panels are not in place, overheat of the terminals,
electric shocks or a fire may be caused.
■ After completing the installation work, check to make
sure that there is no leakage of refrigerant gas.
■ Never directly touch any accidental leaking refrigerant.
This could result in severe wounds caused by frostbite.
■ Electrical work must be carried out in accordance with
the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may
cause electrical shock or fire.
■ Be sure to use a dedicated power circuit. Never use a
power circuit shared by another appliance.
■ For wiring, use a cable long enough to cover the entire
distance with no connection. Do not use an extension
cord. Do not put other loads on the power supply, use a
dedicated power circuit.
Failure to do so may cause abnormal heat, electric
shock, or fire.
■ Do not touch the refrigerant pipes during and
immediately after operation as the refrigerant pipes may
be hot or cold, depending on the condition of the
refrigerant flowing through the refrigerant piping,
compressor and other refrigerant cycle parts. Your hands
may suffer burns or frostbite if you touch the refrigerant
pipes. To avoid injury, give the pipes time to return to
normal temperature or, if you must touch them, be sure
to wear proper gloves.
■ Earth the unit.
Earth resistance should be according to the applicable
legislations.
Do not connect the earth wire to gas or water pipes,
lightning conductor or telephone earth wire.
Incomplete earthing may cause electric shocks.
- Gas pipe.
Ignition or explosion may occur if the gas leaks.
-Water pipe.
Hard vinyl tubes are not effective earths.
- Lightning conductor or telephone earth wire.
Electric potential may rise abnormally if struck by a
lightning bolt.
■ Install the indoor and outdoor units, power wire and
connecting wire at least 1 meter away from televisions or
radios to prevent image interference or noise.
(Depending on the radio waves, a distance of 1 meter
may not be sufficient to eliminate the noise.)
■ Do not rinse the unit. This may cause electric shocks or
fire.
■ Do not install the unit in places such as the following:
- Where there is mist of mineral oil, oil spray or vapour.
Plastic parts may deteriorate, and cause them to fall
out or water to leak.
- Where corrosive gas, such as sulphurous acid gas, is
produced.
Corrosion of copper pipes or soldered parts may
cause the refrigerant to leak.
- Where there is machinery which emits
electromagnetic waves.
Electromagnetic waves may disturb the control
system, and cause malfunction of the equipment.
- Where flammable gases may leak, where carbon
fibre or ignitable dust is suspended in the air or
where volatile flammables, such as thinner or
gasoline, are handled. Such gases may cause a fire.
- Where the air contains high levels of salt such as that
near the ocean.
- Where voltage fluctuates a lot, such as that in
factories.
- In vehicles or vessels.
- Where acidic or alkaline vapour is present.
CAUTION
■ For use of units in applications with temperature
alarm settings it is advised to foresee a delay of 10
minutes for signalling the alarm in case the alarm
temperature is exceeded. The unit may stop for
several minutes during normal operation for
"defrosting of the unit" or when in "thermostat-stop"
operation.
Содержание
- Installation manual 1
- Unit for air to water heat pump system 1
- Daikin europe n v 2
- Ebhq006bbv3 ekcbh008b v3 ebhq006bbv3 ekcbx008b v3 ebhq008bbv3 ekcbh008b v3 ebhq008bbv3 ekcbx008b v3 2
- En60335 2 40 2
- Jean pierre beuselinck director ostend 2nd of may 2013 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 ec 2
- P350991 1 2
- Installation manual 3
- Ontents 3
- Afety precautions 4
- Efinitions 4
- Meaning of used terms 4
- Meaning of warnings and symbols 4
- Combination and options 6
- Connection to a benefit kwh rate power supply 6
- General information 6
- Heating cooling units and heating only units 6
- Model identification 6
- Ntroduction 6
- Scope of the manual 6
- 2 3 5 4 7
- For access to the terminals following panels have to be removed as shown in the figure below 7
- Opening of the outdoor unit to gain access to the unit the service panels need to be opened as shown in the figure below 7
- Main components of the outdoor unit 8
- Electing an installation location 9
- Functional diagram of outdoor hydraulic compartment 9
- General precautions on outdoor installation location 9
- Main components of the outdoor unit switch box 9
- Place of installation 10
- Selecting an outdoor location in cold climates 10
- Wheater dependent precautions 10
- Dimensions of the outdoor unit 11
- Handling 11
- Handling and unpacking the unit 11
- Imensions and service space 11
- Inspection 11
- Nspectin 11
- Service space of the outdoor unit 11
- Ypical application examples 11
- Checking the water circuit 13
- Checking the water volume and expansion vessel pre pressure 13
- Iping connection work 13
- Connecting the water circuit 14
- Setting the pre pressure of the expansion vessel 14
- Protecting the water circuit against freezing 15
- Charging water 16
- Initial start up at low ambient temperatures 16
- Lectrical wiring work 16
- Mportant information regarding the refrigerant used 16
- Piping insulation 16
- Up and configuration 16
- Water piping freezing prevention 16
- Est run and final check 17
- Final check 17
- Pre run checks 17
- Procedure 17
- Test run operation manual 17
- Underfloor heating screed dry out program 17
- Aintenance and service 18
- Checks 18
- Maintenance activities 18
- Maintenance introduction 18
- Peration of the unit 18
- Service precautions 18
- General guidelines 19
- General symptoms 19
- Roubleshooting 19
- Service mode operation 19
- Electrical specifications 20
- Error codes 20
- Isposal requirements 20
- Nit specifications 20
- Technical specifications 20
Похожие устройства
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Сертификат
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Сертификат
- Foodatlas H001 Инструкция по эксплуатации
- Foodatlas H001 Сертификат
- Foodatlas PS-1 Инструкция по эксплуатации
- Foodatlas PS-1 Сертификат
- Foodatlas SM-1388 Инструкция по эксплуатации
- Foodatlas SM-1388 Сертификат
- Daikin EBLQ05C2V3 Руководство по монтажу
- Daikin EBLQ05C2V3 Общие правила техники безопасности
- Daikin EBLQ05C2V3 Руководство по применению для установщика
- Daikin EBLQ07C2V3 Руководство по монтажу
- Daikin EBLQ07C2V3 Руководство по применению для установщика
- Daikin EBLQ07C2V3 Общие правила техники безопасности
- Foodatlas KCB-1Y Инструкция по эксплуатации
- Foodatlas KCB-1Y Сертификат
- Foodatlas KCB-1F Инструкция по эксплуатации
- Foodatlas KCB-1F Сертификат