Einhell BT-AC 190/6 OF [17/80] Possible causes of failure

Einhell BT-AC 190/6 OF [17/80] Possible causes of failure
GB
- 17 -
10. Possible causes of failure
Problem Cause Solution
The compressor
does not start
1. No supply voltage
2. Insu cient supply voltage
3. Outside temperature is too low
4. Motor is overheated
1. Check the supply voltage, the pow-
er plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5°C.
4. Allow the motor to cool down If
necessary, remedy the cause of the
overheating.
The compressor
starts but there is no
pressure
1. Leak in the non-return valve
2. The seals are damaged.
3. The drainage screw for
condensation water (11) leaks.
1. Replace the non-return valve
2. Check the seals and have any da-
maged seals replaced by a service
center
3. Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
1. Loose hose connections
2. Leak in a quick-lock coupling
3. Insu cient pressure set on the
pressure regulator.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Open the pressure regulator further.
Anl_BT_AC_190_6_OF_SPK7.indb 17Anl_BT_AC_190_6_OF_SPK7.indb 17 19.04.12 08:2819.04.12 08:28