Daikin ERSQ016AAY1 [27/459] Specifications

Daikin ERRQ011AAY1 [27/459] Specifications
Daikin Altherma High Temperature • Outdoor units • ERRQ-AAY1
Heating Daikin Altherma
24
2 Specifications
2
2
Refrigerant Type R-410A
Charge kg 4.5 4.5 4.5
Control Expansion valve(electronic type)
Nr of Circuits 1 1 1
Refrigerant Oil Type Daphne FVC68D
Charged Volume l 1.5 1.5 1.5
Piping connections Liquid (OD) Quantity 1 1 1
Type Flare connection
Diameter (OD) mm 9,52
Gas Quantity 1 1 1
Type Flare connection
Diameter (OD) mm 15,9
Drain Quantity 3 3 3
Diameter (OD) mm 26x3
Piping Length Minimum m 3 3 3
Maximum m 50 50 50
Equivalent m 63 63 63
Chargeless m 10 10 10
Additional Refrigerant Charge kg/m See installation manual
Installation height
difference
Maximum m 30 30 30
Heat Insulation Both liquid and gas pipes
Defrost Method Reverse cycle
Defrost Control Sensor for outdoor heat exchanger temperature
Capacity Control Method Inverter controlled
Safety Devices High pressure switch
Fan motor thermal protector
Inverter overload protector
PC board fuse
Standard Accessories Item Installation manual
Quantity 1 1 1
High pressure side Design pressure bar 40 40 40
Notes See operation range drawing
2-3 Electrical Specifications ERRQ011AAY1 ERRQ014AAY1 ERRQ016AAY1
Power Supply Name Y1
Phase 3~
Frequency Hz 50 50 50
Voltage V 380-415
Voltage range Minimum V 342
Maximum V 440
Current Maximum running
Current
Heating A 13,5
Recomended fuses A 16 16 16
Wiring connections For Power Supply Quantity 4G
Remark Select diameter and type according to national and local regulations
For connection with
indoor
Quantity 2 2 2
Remark F1+F2
Power Supply Intake Both indoor and outdoor unit
2-2 Technical Specifications ERRQ011AAY1 ERRQ014AAY1 ERRQ016AAY1