Daikin ERSQ011AAV1 [322/459] Capacity tables
Heating Daikin Altherma
319
Daikin Altherma Low Temperature • Monobloc • EBLQ011-016BA6W1
4 Capacity tables
4 - 1 Heating capacity tables
17
4
EBLQ-B6W1
Maximum Heating Capacity (Peak values)
Maximum Heating Capacity (integrated values)
3TW58012-1C
SYMBOLS
CC : Cooling capacity at maximum operating frequency, measured acc. Eurovent
6/C/003-2006 (kW)
HC : Heating capacity at maximum operating frequency, measured acc. Eurovent
6/C/003-2006 (kW)
PI : Power input (kW), measured acc. Eurovent 6/C/003-2006 (kW)
LWE : Leaving Water Evaporator temperature (°C)
LWC : Leaving Water Condensor temperature (°C)
Tamb : Ambient temperature RH=85%
Heating capacity at heat recovery condenser
1 Cooling capacity
Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for
chilled water range Dt = 38°C
Capacity values may not be extrapolated below 7°C leaving water temperature
2 Heating capacity
Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for
chilled water range Dt = 38°C
3 Power input
Power input is total of indoor and outdoor unit, except the circulation pump;
according to Eurovent rating standard 6/C/003-2006.
Pump power input to be added = 90 W (according EN14511).
NOTES:
-For the model with heatertape (*(D:V)LQ): when ambient temperature becomes
lower than ’X’: bottomplate heater power input to be added = 95W
1) For AA models: ’X’ = 4°C
2) For BA models: ’X’ = [F-02] = BPH ON temp for more details see
installationmanual of indoor unit.
NOTES
(a) only E(D/B)L*
101727_BW_EN_004_464_IC.pdf 323 9/06/2010 14:55:20