Daikin ERSQ016AAY1 [386/459] Capacity tables

Daikin ERSQ011AAV1 [386/459] Capacity tables
Heating Daikin Altherma
383
Indoor units • FWXV-A
3 Capacity tables
3 - 1 Heating capacity tables
20
3
FWXV15-20A
Heating capacity tables
Air temperature (°C) 20°C
Water temperature (Entering °C - leaving °C) 35°C-30°C 45°C-40°C 50°C-45°C 55°C-45°C 60°C-50°C
Model Fan
Heating
capacity
Water
flow
Water
pressure
drop
Heating
capacity
Water
flow
Water
pressure
drop
Heating
capacity
Water
flow
Water
pressure
drop
Heating
capacity
Water
flow
Water
pressure
drop
Heating
capacity
Water
flow
Water
pressure
drop
kW L/min kPa kW L/min kPa kW L/min kPa kW L/min kPa kW L/min kPa
Air temperature (°CDB-°CWB) 22°CDB
Water temperature (Entering °C - leaving °C) 35°C-30°C 45°C-40°C 50°C-45°C 55°C-45°C 60°C-50°C
Model Fan
Heating
capacity
Water
flow
Water
pressure
drop
Heating
capacity
Water
flow
Water
pressure
drop
Heating
capacity
Water
flow
Water
pressure
drop
Heating
capacity
Water
flow
Water
pressure
drop
Heating
capacity
Water
flow
Water
pressure
drop
kW L/min kPa kW L/min kPa kW L/min kPa kW L/min kPa kW L/min kPa
3D066680
101727_BW_EN_004_464_IC.pdf 387 9/06/2010 14:55:44