HPP CLW 80/100 (1150 об/мин) [19/84] Caution the temperature of the water supply is a crucial factor for the life and performance of the pump to use water at temperatures above 40 c 104 f follow the instructions in the following paragraph operation at a temperature above max value during suction the pump must be fitted with an adequately sized filter the filtering system must have the following characteristics filtering power between 100 320 microns

HPP CLW 100/100 (1450 об/мин) [19/84] Caution the temperature of the water supply is a crucial factor for the life and performance of the pump to use water at temperatures above 40 c 104 f follow the instructions in the following paragraph operation at a temperature above max value during suction the pump must be fitted with an adequately sized filter the filtering system must have the following characteristics filtering power between 100 320 microns
19
tank wall
tank
lter
bypass line
pump head
valve
pressure gauge
accumulator
safety valve
BYPASS RECIRCULATION DURING SUCTION
“T CONNECTIONS
90° CURVES
DIAMETER
REDUCTION
NEGATIVE HEAD
valve
lter
accumulator
pressure gauge
pump head
tank
OVERTURNED “U” CURVES
safety valve
YES
NO
OUT
BY-PASS
OUT
BY-PASS
Fig. 2
CAUTION
The temperature of the water supply is a crucial factor for the life and performance of the pump.
To use water at temperatures above 40 °C/104 °F, follow the instructions in the following paragraph Operation
at a temperature above max value”.
During suction, the pump must be tted with an adequately sized lter.
The ltering system must have the following characteristics:
- ltering power between 100-320 microns;