Hitachi CG18DSDL [18/152] English

Hitachi CG18DSDL [18/152] English
18
English
Table 1
Indications of the pilot lamp (UC18YGSL)
Pilot lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o for 0.5 seconds)
While
charging
Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o for 0.5 seconds)
Overheat
standby
Blinks
Lights for 1 second. Does not light for 0.5
seconds. (o for 0.5 seconds)
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
Charging
impossible
Flickers
Lights for 0.1 seconds. Does not light for 0.1
seconds. (o for 0.1 seconds)
Malfunction in the
battery or the charger
Indications of the pilot lamp (UC18YRSL)
Pilot lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o for 0.5 seconds)
While
charging
Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o for 0.5 seconds)
Charging
impossible
Flickers
Lights for 0.1 seconds. Does not light for 0.1
seconds. (o for 0.1 seconds)
Malfunction in the
battery or the charger
Pilot lamp
(green)
Overheat
standby
Lights
Lights continuously
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
(2) Regarding the temperatures of the rechargeable
battery
The temperatures for rechargeable batteries are as
shown in the Table 2, and batteries that have become
hot should be cooled for a while before being recharged.
Table 2 Recharging ranges of batteries
Temperatures at which the battery can be recharged
0°C – 5C
(3) Regarding recharging time
Table 3 shows the recharging time required according
to the type of battery.
Table 3 Charging time (At 20°C)
Charger
Battery
UC18YGSL UC18YRSL
BSL1430 Approx. 90 min. Approx. 45 min.
BSL1830 Approx. 90 min. Approx. 45 min.
NOTE
The recharging time may vary according to the ambient
temperature.
4. Disconnect the charger’s power cord from the
receptacle.
5. Hold the charger rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might be
low when using them the rst and second time. This is
a temporary phenomenon, and normal time required for
recharging will be restored by recharging the batteries
2 – 3 times.
How to make the batteries perform longer
(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the battery
and recharge it after it has cooled for a while.