Step 3 3 Remove the adapter and hose connection from the suction line port and replace the cap ENGLISH Step 3 4A 3 4B Remove the cap from the liquid line valve Using the hex wrench open the valve then replace and tighten the cap Step 3 3 Step 3 4A Step 3 4B Step 3 5A Step 3 5B Step 3 6 Step 3 5 A 3 5B Remove the cap from the suction line valve Using the hex wrench open the valve then replace and tighten the cap Step 3 6 Wrap the lineset drain line and wiring starting at the bottom of the bundle with an overlap type wrap concluding at the piping hole Use a sealant to seal the piping hole opening to prevent weather elements from entering the building Illustration 6 Verify the condensate drain line has a constant pitch downward for proper water flow There should be no kinks or rises in the tubing which may cause a trapping effect resulting in the failure of the condensate to exit the piping Illustration 6 SECTION A INSTALLATION PAGE 9