Haier 1U25S2PJ1FA [22/77] Domestic air conditioner

Содержание

Haier Functions and control value of the middle 2 values take the mean value Abnormal stop Decreasing the frequency rapidly 1 HZ second Decreasing the frequency slowly 1HZ 10seconds The frequency doesn t change Increasing the frequency 1HZ 10second Increasing the frequency 1HZ 1 second TTC 115 C lasts for 20 seconds Overheating protection of air blowing alarm malfunction to the indoor others don t last 7 1 4 2 TC high temperature preventing control of the indoor heating unit Tpgjndoor is the highest value of the effective indoor unit start it and it is in accord with the running state TC indoor coil temp The indoor heat exchanger sensor tests the temperature of the indoor heat exchanger If the temperature is higher than 55 C decrease the rotate speed of the compressor and do the high temperature preventing protection of the indoor heat exchanger if the temperature of the indoor heat exchanger is lower than 47 C recover to the normal control TC C FghJ1 2 62 C FghJ2 2 58C The compressor stops FghJ1 63 C N Decreasing the frequency rapidly P Decreasing the frequency slowly FghJ2 60 C FghJ3 56 C Q Prohibiting increasing the frequency FghJ4 53 C R Increasing slowly FghJ5 47 C Fgh t3 2 FghJ4 2 Fgh t5 2 Normal N Decreasing at the speed of 1 HZ 1 second P Decreasing at the speed of 1Hz 10 seconds Q Continue to keep the last time instruction cycle R Increasing at the speed of 1Hz 10seconds 7 1 4 3 Anti freezing protection of the indoor heat exchanger When refrigerating heating prevent freezing Tpgjndoor is the minimum value of the effective indoor unit start it and it is in accord with the running state Haier 20 Domestic air conditioner