Haier ADH250H1ERG [2/28] Important information rega rding the refrigerant used
![Haier ADH250H1ERG [2/28] Important information rega rding the refrigerant used](/views2/1812488/page2/bg2.png)
2
Your air conditioning product is marked with this
symbol.This means that electrical and electronic
products shall not be mixed with unsorted
household waste.Do not try to dismantle the
system yourself:the dismantling of the air
conditioning system,treatment of the refrigerant,of oil and of
other part must be done by a qualified installer in accordance
with relevant local and national legislation.Air conditioners
must be treated at a specialized treatment facility for reuse,
recycling and recovery.By ensuring this product is disposed
of correctly,you will help to prevent potential negative cons-
equences for the environment and human health.Please
contact the installer or local authority for more information.
Battery must be removed from the remote controller and dis-
posed of separately in accordance with relevant local and
national legislation.
DISPOSAL REQUIREMENTS:
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
This product contains fluorinated greenhouse gases covered
by the Kyoto Protocol.Do not vent into the atmosphere.
Refrigerant type:R410A
GWP:2088
GWP=global warming potential
Please fill in with indelible ink,
1 the factory refrigerant charge of the product
2 the additional refrigerant amount charged in the field
and
1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the
product charging port(e.g.onto the inside of the stop value
cover).
A contains fluorinated greenhouse gases covered by the
Kyoto Protocol
B factory refrigerant charge of the product:see unit name
plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED
Haier Industrial Park,Qianwangang Road,Eco-Tech Development Zone,Qingdao 266555,Shandong,P.R.C.
A
B
C
D
kg
kg
kg
R410A
WARNING
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use
of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
The appliances are not intended to be operated by means of an external timer or separate remote-control system.
Keep the appliance and its cord out of reach of children less than 8 years.
The A-weighted sound pressure level is below 70 dB.
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial
use by lay persons
Air conditioner working temperature: cooling 10~43 degree, heating -15~24 degree.
Содержание
- Adh071m1erg adh071m3erg adh090m1erg 1
- Adh105h1erg adh125h1erg adh140h1erg adh160h1erg 1
- Adh105m1erg adh125m1erg adh140m1erg 1
- Adh200h1erg adh250h1erg 1
- Contents 1
- Duct type air conditioner operation manual and installation manual 1
- Keep this operation manual for future reference 1
- This product must only be installed or serviced by qualified personnel please read this manual carefully before installation 1
- Disposal requirements 2
- Important information rega rding the refrigerant used 2
- Warning 2
- Cautions 3
- We recommend that you read this instruction manual carefully before using your air conditioner to gain full advantage of the functions and to avoid malfunction due to mishandling or incorrect operation the precautions described below are warnings and cautions these are very important precautions concerning safety be sure to observe all of them without fail 3
- Cautions 4
- Before starting to use the system read carefully this safety precautions to ensure a proper operation of the system safety precautions described here are classified to warning and caution precautions which are shown in the column of waning means that an improper handing could lead to a grave result like a death serious injury etc however even if precautions are shown in the column of caution a very serious problem could occur depending on situation make sure to observe these safety precautions faithfully because they are very important information to ensure the safety symbols which appear frequently in the text have following meanings 5
- Cautions for installation 5
- Cautions for transfer or repair 5
- Safety precautions 5
- Strictly prohibited observe instructions faithfully provide a positive grounding 5
- When you have read through the manual keep it always at hand for read consultation if the operator is replaced make sure to hand over this manual to the new operator 5
- Cautions for operation 6
- Safety precautions 6
- Adh071m3erg 7
- Adh105 125 140 160 200 250h1erg static pressure level selection can also be achieved by infrared remote controller method is step a set the infrared remote controller at condition fan mode fan speed high step b then aim the remote controller at the infrared remote receiver re 02 press health button 4 n times 1 n 7
- Adh200h1erg adh250h1erg 7
- All the cables shall have got the european authentication certificate during installation when the connecting cables break off it must be assured that the grounding wire is the last one to be broken off 6 the power cable and connect cable should be self provided 7 the breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less than 3mm 8 the indoor unit installation height is at least 2 m 9 a leakage breaker must be installed 10 10 for adh071m1erg adh090m1erg we can get the 4 different esp through adjust the indoor unit pcb sw1 4 and sw1 5 please refer below 7
- Applicable ambient temperature range the machine is adaptive in following situation 7
- Attention cut off the power supply to adjust the sw1 4 and sw1 5 or else the operation is invalid 10 for adh071m3erg adh105m1erg adh125m1erg adh140m1erg adh105h1erg adh125h1erg adh140h1erg adh160h1erg adh200h1erg adh250h1erg you can select 10 levels static pressure 2 level is the factory default static pressure level for different models even the static pressure level is the same the actual static pressure value is different static pressure selection need achieved by wired controller refer wired controller s manual to get details 7
- Factory default 7
- For ad105 125 140m1erg 7
- If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 3 if the fuse on the indoor pc board is broken please change it with the type of t 3 5a 250v for adh105 adh125 adh140m1erg or the type t5a 250v for adh071m1erg adh071m3erg adh090m1erg t8a 250v for adh105 125 140 160h1erg adh200h1erg adh250h1erg 4 the wiring method should be in line with the local wiring standard 5 the power cable should be h05rn f 3g 4 m 7
- Integer within 12 seconds then the receiver will beep n 1 times the static pressure level n is been set successfully 7
- Note for infrared remote controller yr hbs01 need press on off button make the controller s at off status first then open the button cover press fresh button will enter fan mode interface 7
- Outdoor unit 1uh071 090 105n1erg or h05rn f 3g 6 m 7
- Outdoor unit 1uh125 140 160p1erg or h05rn f 5g 4 m 7
- Outdoor unit 1uh125 140p1ek or h05rn f 5g 4 m 7
- Outdoor unit 1uh200 250w1erk the connecting cable should be h05rn f4g 2 m 7
- Safety precautions 7
- Adh071m1erg 8
- Adh071m3erg 8
- Adh090m1erg 8
- Adh105h1erg adh125h1erg adh140h1erg adh160h1erg 8
- Adh105m1erg adh125m1erg adh140m1erg 8
- Adh250h1erg adh200h1erg 8
- Parts and functions 8
- Parts and functions 9
- Heating mode 10
- Care and maintenance 11
- Troubleshooting 12
- Indoor unit trouble shooting 13
- Troubleshooting 13
- Accessories 14
- Accessories 15
- Precaution for installation 16
- Is the unit installed correctly 17
- Installation procedure 18
- Installation procedure 19
- Installation procedure 20
- Installation procedure 21
- Installation procedure 22
- Installation procedure 23
- Installation procedure 24
- Installation procedure 25
- Move and scrap the air conditioning 26
Похожие устройства
- Haier ADH250H1ERG Сервис мануал
- Haier PB-950KB Сервис мануал
- Haier PB-950MB Сервис мануал
- Haier AS09PBDHRA Инструкция по эксплуатации
- Haier AS12PBDHRA Инструкция по эксплуатации
- Haier AS18PDDHRA Инструкция по эксплуатации
- Haier AS24PDDHRA Инструкция по эксплуатации
- Haier AS26PBDHRA Брошюра
- Haier AS26PBDHRA Инструкция по эксплуатации
- Haier AS35PBDHRA Брошюра
- Haier AS35PBDHRA Инструкция по эксплуатации
- Haier AS53PDDHRA Брошюра
- Haier AS53PDDHRA Инструкция по эксплуатации
- Haier AS71PDDHRA Брошюра
- Haier AS71PDDHRA Инструкция по эксплуатации
- Haier 1U09MADFRA Инструкция по монтажу
- Haier 1U12MADFRA Инструкция по монтажу
- Haier 1U18WADFRA Инструкция по монтажу
- Haier 1U24WADFRA Инструкция по монтажу
- Haier 1U26MADFRA Инструкция по монтажу