Haier ADH250H1ERG [6/28] Safety precautions
![Haier ADH250H1ERG [6/28] Safety precautions](/views2/1812488/page6/bg6.png)
Do not wash the air conditioner with water.
Do not install the system where the air outlet
reaches directly the flora and fauna.
Make sure to use a fuse of proper electric rating.
Do not operate the system while the air outlet grill
is removed.
It is strictly prohibited to place a container of
combustible gas or liquid near the air conditioner
or to spray it directly with the gas or liquid.
Neither stand on the air conditioner nor
place something on it.
Do not use the power switch to turn on or off the
system.
Do not touch the air outlet section while the swing
louver is operating.
Do not use such equipment as a water heater, etc.
around the indoor unit or the wire controller.
ON
OFF
It could cause electric shocks. It will not be good for their health. Use of steel or copper wire in place of a fuse is
strictly prohibited because it could result in a trouble
or fire accident.
There is a risk of injury.It could cause a fire accident.There are risks of falling or injury by collapsed
object.
It could cause a fire or water leakage. There is a risk of injury. If the system is operated at the vicinity of such
equipment which generates steam, condensed
water may drip during cooling operation or it could
cause a fault current or short-circuit.
When operating the system simultaneously with
a combustion apparatus, indoor air must be
ventilated frequently.
Check occasionally the support structure of the
unit for any damage after a use of long period of
time.
Insufficient ventilation could cause an oxygen
deficiency accident.
If the structure is not repaired immediately, the
unit could topple down to cause a personal injury.
When cleaning the system, stop the operation and
turn off the power switch.
Do not put water containers on the unit such as a flower vase, etc.
Cleaning should never be done while the internal
fans are running with high speed.
If the water enters into the unit and damages the electric insulation material, it may cause electric shock.
WARNING
CAUTION
CAUTIONS FOR OPERATION
You should refrain from exposing your body directly
to cool wind for a long time.
Do not poke the air inlet or outlet with a bar, etc. When any abnormal condition (scorching smell or
others) is found, stop the operation immediately
and turn off the power switch. Then consult your
dealer.
It could affect your physical condition or cause
some health problems.
Since the internal fan is operating with a high
speed, it could cause an injury.
If you continue the operation without removing the
cause, it could result in a trouble, electric shock
or fire.
The system should never be used for any other
purposes than intended such as for preservation
of food, flora and fauna, precision devices or work
of art.
Do not handle switches with a wet hand. Combustion apparatus should not be placed
allowing a direct exposure to wind of air conditioner.
Incomplete combustion could occur on the
apparatus.
It could cause electric shocks.It could cause deterioration of food or other
problems.
6
Safety Precautions
Содержание
- Adh071m1erg adh071m3erg adh090m1erg 1
- Adh105h1erg adh125h1erg adh140h1erg adh160h1erg 1
- Adh105m1erg adh125m1erg adh140m1erg 1
- Adh200h1erg adh250h1erg 1
- Contents 1
- Duct type air conditioner operation manual and installation manual 1
- Keep this operation manual for future reference 1
- This product must only be installed or serviced by qualified personnel please read this manual carefully before installation 1
- Disposal requirements 2
- Important information rega rding the refrigerant used 2
- Warning 2
- Cautions 3
- We recommend that you read this instruction manual carefully before using your air conditioner to gain full advantage of the functions and to avoid malfunction due to mishandling or incorrect operation the precautions described below are warnings and cautions these are very important precautions concerning safety be sure to observe all of them without fail 3
- Cautions 4
- Before starting to use the system read carefully this safety precautions to ensure a proper operation of the system safety precautions described here are classified to warning and caution precautions which are shown in the column of waning means that an improper handing could lead to a grave result like a death serious injury etc however even if precautions are shown in the column of caution a very serious problem could occur depending on situation make sure to observe these safety precautions faithfully because they are very important information to ensure the safety symbols which appear frequently in the text have following meanings 5
- Cautions for installation 5
- Cautions for transfer or repair 5
- Safety precautions 5
- Strictly prohibited observe instructions faithfully provide a positive grounding 5
- When you have read through the manual keep it always at hand for read consultation if the operator is replaced make sure to hand over this manual to the new operator 5
- Cautions for operation 6
- Safety precautions 6
- Adh071m3erg 7
- Adh105 125 140 160 200 250h1erg static pressure level selection can also be achieved by infrared remote controller method is step a set the infrared remote controller at condition fan mode fan speed high step b then aim the remote controller at the infrared remote receiver re 02 press health button 4 n times 1 n 7
- Adh200h1erg adh250h1erg 7
- All the cables shall have got the european authentication certificate during installation when the connecting cables break off it must be assured that the grounding wire is the last one to be broken off 6 the power cable and connect cable should be self provided 7 the breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less than 3mm 8 the indoor unit installation height is at least 2 m 9 a leakage breaker must be installed 10 10 for adh071m1erg adh090m1erg we can get the 4 different esp through adjust the indoor unit pcb sw1 4 and sw1 5 please refer below 7
- Applicable ambient temperature range the machine is adaptive in following situation 7
- Attention cut off the power supply to adjust the sw1 4 and sw1 5 or else the operation is invalid 10 for adh071m3erg adh105m1erg adh125m1erg adh140m1erg adh105h1erg adh125h1erg adh140h1erg adh160h1erg adh200h1erg adh250h1erg you can select 10 levels static pressure 2 level is the factory default static pressure level for different models even the static pressure level is the same the actual static pressure value is different static pressure selection need achieved by wired controller refer wired controller s manual to get details 7
- Factory default 7
- For ad105 125 140m1erg 7
- If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 3 if the fuse on the indoor pc board is broken please change it with the type of t 3 5a 250v for adh105 adh125 adh140m1erg or the type t5a 250v for adh071m1erg adh071m3erg adh090m1erg t8a 250v for adh105 125 140 160h1erg adh200h1erg adh250h1erg 4 the wiring method should be in line with the local wiring standard 5 the power cable should be h05rn f 3g 4 m 7
- Integer within 12 seconds then the receiver will beep n 1 times the static pressure level n is been set successfully 7
- Note for infrared remote controller yr hbs01 need press on off button make the controller s at off status first then open the button cover press fresh button will enter fan mode interface 7
- Outdoor unit 1uh071 090 105n1erg or h05rn f 3g 6 m 7
- Outdoor unit 1uh125 140 160p1erg or h05rn f 5g 4 m 7
- Outdoor unit 1uh125 140p1ek or h05rn f 5g 4 m 7
- Outdoor unit 1uh200 250w1erk the connecting cable should be h05rn f4g 2 m 7
- Safety precautions 7
- Adh071m1erg 8
- Adh071m3erg 8
- Adh090m1erg 8
- Adh105h1erg adh125h1erg adh140h1erg adh160h1erg 8
- Adh105m1erg adh125m1erg adh140m1erg 8
- Adh250h1erg adh200h1erg 8
- Parts and functions 8
- Parts and functions 9
- Heating mode 10
- Care and maintenance 11
- Troubleshooting 12
- Indoor unit trouble shooting 13
- Troubleshooting 13
- Accessories 14
- Accessories 15
- Precaution for installation 16
- Is the unit installed correctly 17
- Installation procedure 18
- Installation procedure 19
- Installation procedure 20
- Installation procedure 21
- Installation procedure 22
- Installation procedure 23
- Installation procedure 24
- Installation procedure 25
- Move and scrap the air conditioning 26
Похожие устройства
- Haier ADH250H1ERG Сервис мануал
- Haier PB-950KB Сервис мануал
- Haier PB-950MB Сервис мануал
- Haier AS09PBDHRA Инструкция по эксплуатации
- Haier AS12PBDHRA Инструкция по эксплуатации
- Haier AS18PDDHRA Инструкция по эксплуатации
- Haier AS24PDDHRA Инструкция по эксплуатации
- Haier AS26PBDHRA Брошюра
- Haier AS26PBDHRA Инструкция по эксплуатации
- Haier AS35PBDHRA Брошюра
- Haier AS35PBDHRA Инструкция по эксплуатации
- Haier AS53PDDHRA Брошюра
- Haier AS53PDDHRA Инструкция по эксплуатации
- Haier AS71PDDHRA Брошюра
- Haier AS71PDDHRA Инструкция по эксплуатации
- Haier 1U09MADFRA Инструкция по монтажу
- Haier 1U12MADFRA Инструкция по монтажу
- Haier 1U18WADFRA Инструкция по монтажу
- Haier 1U24WADFRA Инструкция по монтажу
- Haier 1U26MADFRA Инструкция по монтажу