Karcher PC 100 M2 BIO [16/244] Function

Karcher PC 100 M2 BIO [16/244] Function
– 2
Do not fill in solvents, inflammable or
explosive liquids.
The appliance must be installed on a
horizontal, firm base that does not allow
liquids to seep in.
The device is not meant for disposing
off old oil. If large quanties of oil, petrol,
engine oil, anti-frost agents or similar
substances enter the device this can
hamper the bio-degradation of oil/
grease by the microbes.
The device is not meant for cleaning
painting tools.
The appliance is not suited for the use
in potentially explosive environments.
When using the appliance, the operator
stands in front of it.
The detergent in the container is heated by
the heating element and transported by the
pump to the cleaning tools. These can then
be controlled via the corresponding shut-off
valves.
Solid dirt particles are held back by the
sieve in the rinsing floor or in the underlying
filter mat.
Grease and oily dirt is rinsed back into the
container and is there degraded by the mi-
crobes into carbon dioxide and water.
The microbes are first caught in the filter
mat and are then transported by the liquid
detergent into the container. The liquid de-
tergent must be heated in the container so
that the microbes can function optimally.
Please read the operating instructions
for your machine before using it, and
pay particular attention to the following
safety instructions.
Warning and information plates on the
machine provide important directions
for safe operation.
In addition to the information contained
in the operating instructions, all statuto-
ry safety and accident prevention regu-
lations must be observed.
Danger
Immediate danger that can cause severe
injury or even death.
Warning
Possible hazardous situation that could
lead to severe injury or even death.
Caution
Possible hazardous situation that could
lead to mild injury to persons or damage to
property.
Danger
Danger of injury by electric shock.
The appliance may only be connected to al-
ternating current.
The appliance may only be connected to an
electrical supply which has been installed in
accordance with IEC 60364.
The voltage indicated on the type plate
must correspond to the voltage of the elec-
trical source.
Please do not let mineral oil contaminat-
ed waste water reach soil, water or the
sewage system.
Please dispose off used filter mats ac-
cording to the local regulations for waste
containing mineral oil.
Workstation
Function
Safety instructions
Symbols in the operating instruc-
tions
Symbols on the machine
Danger
Risk of electric shock. The
casing must only be
opened by electricians.
Power connection
!
16 EN