Haier HSU-12HF03(B) [20/28] Emergency operation

Содержание

Emergency operation Use this operation only when the remote controller is defective or lost When the emergency operation switch is pressed the Pi sound is heard once which means the start of this operation In this operation the system automatically selects the operation modes cooling or heating according to the room temperature as follows Temperature Operation Designated temperature mode Timer mode Air flow ABOVE 23 C COOLING 26 C CONTINUOUS AUTOMATIC BELOW 23 C HEATING 23 C CONTINUOUS AUTOMATIC It is not possible to operate in dry mode Test operation Test operation switch is the same as emergency switch Use this switch in the test operation when the room temperature is below 16 C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed Hi After 30 minutes test opretation ends automatically Press the emergency operation switch once more or manipulate through the remote controller the Pi sound the emergency or test operation is terminated When the remote controller is manipulated it gets the system back to the normal operation mode 18