Haier HSU-12HF03(B) [20/28] Emergency operation
Содержание
- Inverter room air conditioner 1
- Operation manual 1
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Safety instructions and warnings 3
- Specifications 4
- A caution 5
- Installation 5
- Warning 5
- A caution 6
- A warning 6
- Operation mode indicato 7
- After installation the power plug should be easily reached 9
- If the fuse on pc board is broken please change it with the type of 9
- If the supply cord is damaged it must be replaced by the manufacturer or 9
- Its service agentor a similar qualified person 9
- Supervision 9
- T 5a 250v 9
- The appliance 9
- The appliance is not intended for use by young children or infirm persons without 9
- The distance between the indoor unit and the floor should be more than 2m 9
- The machine is adaptive in following situation 1 applicable ambient temperature range 9
- The type of connecting wire is h05rn f3g2 m 9
- The waste battery should be disposed properly 9
- The wiring method should be in line with the local wiring standard 9
- W young children should be supervised to ensure that they do not play with 9
- Buttons and display of the remote controller 10
- Parts and functions 10
- Attach the lid 11
- Handling the wireless remote controller 11
- Insert the dry batteries 11
- Inserting dry batteries 11
- Remove the lid 11
- Verify by the indicators 11
- A caution 12
- As its front side faces to the front 12
- Attach air purifying filter 12
- Attach the standard air filter 12
- Attachment of air purifying filter 12
- Close the inlet grille 12
- Detach the standard air filter 12
- Open the inlet grille 12
- Fixing the flow direction 15
- Horizontal adjustment 15
- Swing of air flow 15
- Vertical adjustment 15
- Power mode operation includes super mode operation and soft mode operation 16
- Press power mode switch once 16
- Press power mode switch twice 16
- This mode is good to have yourself blown directly to feel cooler or warmer 16
- Power mode operation includes super mode operation and soft mode operation 17
- Press power mode switch once 17
- Press power mode switch twice 17
- Soft mode operation 17
- Soft mode operation operating more quietly by controlling the air flow of indoor unit it is useful when noises should be smaller such as for reading and sleeping 17
- Z c note 17
- Timer off function 18
- Timer cancellation 19
- Timer on function 19
- Emergency operation 20
- Test operation 20
- Air filter cleaning 22
- Do not use the following for cleaning 22
- Remote controller indoor body 22
- Warning 22
- Attach the grille 23
- Caution 23
- Detach the grille 23
- Open the inlet grille 23
- Wash the grille 23
- A caution 24
- Attach new air purifying filter 24
- Attach the standard air filter as 24
- Close the inlet grille 24
- Detach the air purifying filter 24
- Detach the standard air filter 24
- Its front side faces to the front 24
- Open the inlet grille 24
- To keep you air conditioner in good condition after season 25
- A caution 26
- 4 note j 27
- A warning 27
- Trouble shooting 27
- When a trouble or abnormality occurred with the machine 27
- Caution 28
- Condition causes or check points 28
- The following is not a machine trouble 28
Похожие устройства
- Haier HSU-12HH03(B) Технические данные
- Haier HSU-12HH03(B) Инструкция по эксплуатации
- Haier HSU-12HT03(B) Технические данные
- Haier HSU-12HT03(B) Инструкция по эксплуатации
- Haier AS142AHAHA Инструкция по эксплуатации
- Haier HSU-14H03(B) Инструкция по эксплуатации
- Haier AU142AEAHA Инструкция по эксплуатации
- Haier AS182ASAHA Инструкция по эксплуатации
- Haier AS182ATAHA Инструкция по эксплуатации
- Haier HSU-18H03(B) Инструкция по эксплуатации
- Haier HSU-18HB03(B) Инструкция по эксплуатации
- Haier AU182AFAHA Инструкция по эксплуатации
- Haier AU182AFAEA Инструкция по эксплуатации
- Haier AU182AFMFA Инструкция по эксплуатации
- Haier AU282AHAFA Инструкция по эксплуатации
- Haier AP182AKAAA Инструкция по эксплуатации
- Haier AP182AZAAA Инструкция по эксплуатации
- AnyTone AT-310M Инструкция по эксплуатации
- AOR AR-3000A Инструкция по эксплуатации
- Baofeng BF-T3 Инструкция по эксплуатации
Emergency operation Use this operation only when the remote controller is defective or lost When the emergency operation switch is pressed the Pi sound is heard once which means the start of this operation In this operation the system automatically selects the operation modes cooling or heating according to the room temperature as follows Temperature Operation Designated temperature mode Timer mode Air flow ABOVE 23 C COOLING 26 C CONTINUOUS AUTOMATIC BELOW 23 C HEATING 23 C CONTINUOUS AUTOMATIC It is not possible to operate in dry mode Test operation Test operation switch is the same as emergency switch Use this switch in the test operation when the room temperature is below 16 C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed Hi After 30 minutes test opretation ends automatically Press the emergency operation switch once more or manipulate through the remote controller the Pi sound the emergency or test operation is terminated When the remote controller is manipulated it gets the system back to the normal operation mode 18