Orient ОС-201 [230/244] Log raw data

Orient ОС-201 [230/244] Log raw data
COMNAV OEM BOARD REFERENCE MANUAL
Chapter 5. Frequently-Used Operations
ComNav Technology Ltd.
211
CNT-OEM-RM001, Rev 1.8
LOG TYPE
SYNCH
NOTE
Recommended
Input
interfacemode com2 none rtcm
fix position 30.123 121.456 50.789
log com2 rtcm1005b ontime 10
log com2 rtcm1104b ontime 1
log com2 rtcm1004b ontime 1
configure port
Identify station position
Set position message
Set BD2 observables message
Set GPS observables message
Set up reference station in RTCMV3 format, outputted from COM2
Command1: LOG COM2 RTCM1004B ONTIME 1
Message 1004 outputted from COM2 every 1 second
Command2: LOG COM2 RTCM1005B ONTIME 5
Message1005 outputted from COM2 every 5 second
Command3: FIX AUTO
Fix reference station coordinates in auto mode
Command4: SAVECONFIG
Save configurations in flash
Set up reference station in RTCMV3 using BD2 observations
Command1: LOG COM3 RTCM1104B ONTIME 1
Message 1104 outputted from COM3 every 1 second
Command2: LOG COM3 RTCM1005B ONTIME 5
Message 1105 outputted from COM3 every 5 second
Command3: REFAUTOSETUP ON
Fix reference station coordinates in auto mode
Command4: SAVECONFIG
Save configurations in flash
5.4 LOG RAW DATA

Содержание

Похожие устройства

Скачать