Orient ОС-201 [58/244] Rtktimeoutset maximum age of rtk data

Orient ОС-201 [58/244] Rtktimeoutset maximum age of rtk data
COMNAV OEM BOARD REFERENCE MANUAL
Chapter 3. Compatible Commands
ComNav Technology Ltd.
39
CNT-OEM-RM001, Rev 1.8
3.2.33 RTKTIMEOUT Set maximum age of RTK data
Format
RTKTIMEOUT <time-delay>
Description
This command is used to set the maximum age of RTK data to use when operating as a rover
station. RTK data received that is older than the specified time is ignored.
Parameters
time-delay less than 200s, default 200s
Example
RTKTIMEOUT 30
3.2.34 RTKQUALITY Set RTK quality level
Format
RTKQUALITY <normal/quick/extra-safe>
Description
Use this command to select an RTK quality mode.
Parameters
normal/extra-safe/quick normal RTK/extra-safe RTK/quick RTK
Quick Efficiency first, and the fixed rate of the fixed solution is guaranteed as far as
possible.
Extra-safe Quality first, ensuring the reliability of the fixed solution as much as possible.
Normal Equilibrium mode.
Example
Rtkqualityevel normal
Notice: for the geomatics application, the default setting: FFT+QUICK mode
For the attitude determination application, the setting: LAND+QUICK mode.