Graco REACTOR 2 H-30 PHH132 Техническая документация онлайн [32/110] 680018

Graco REACTOR 2 H-30 PHH132 Техническая документация онлайн [32/110] 680018
Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
T6DHHose
SensorErrorHose
Disconnectedor
shortedRTDcable
inhoseorbadFTS
ExposeeachhoseRTD
connectiontocheckand
retightenanyloosecon-
nector.MeasurehoseRTD
cableandFTScontinuity.
SeeRepairHeatedHose,
page62.OrderRTDTest
kit24N365formeasure-
ment.
DisconnectthehoseRTD
anduseHoseManualMode
orHoseResistanceModeto
continuethejobuntilrepair
canbecompleted.Hose
ResistanceModerequires
asavedcalibrationfactor.
Refertoyourproportioner
operationmanualtoenable
HoseControlModes.
ShortedRTDcable
inhoseorFTS
ExposeeachhoseRTD
connectiontocheckfor
exposedandshortedRTD
wires.MeasurehoseRTD
cableandFTScontinuity.
SeeRepairHeatedHose,
page62.OrderRTDTest
kit24N365formeasure-
ment.
DisconnectthehoseRTD
anduseHoseManualMode
orHoseResistanceModeto
continuethejobuntilrepair
canbecompleted.Hose
ResistanceModerequires
asavedcalibrationfactor.
Refertoyourproportioner
operationmanualtoenable
HoseControlModes.
T6DT
TCM
SensorErrorTCM
ShortedAorB
HeaterRTD
Iftheerrorstilloccurswith
thehoseFTSunplugged,
oneoftheheaterRTDs
isbad.UnplugtheAor
BRTDfromtheTCM.If
unplugginganRTD󰘰xes
theT6DTerror,replacethe
RTD.
32 334946H