Comprag FR1508-270 [33/120] Staring the compressor

Comprag F1508 [33/120] Staring the compressor
33COMPRAG Screw air compressor A/F-Series
STOP:
Incorrect phase sequence
PHASE REVERSE
STOP:
Three phase power unbalanced
MOTOR UNBALANCE
STOP:
Phase loss detected
PHASE FAILURE C
STOP: TEMP
Temperature sensor error
SENSOR FAULT
STOP: PRESSURE
Pressure sensor error
SENSOR FAULT
4.3 Staring the compressor
Before staring check oil level at sight glass on the Air-Oil separa-
tion tank.
Switch on the voltage. Open the air outlet valve. Press button
”Start” on the control panel.
The compressor starts running in an automatic operation mode, controlled by the e-Log elec-
tronic controller.
4.4 Switching off the compressor
To stop the compressor in the case of emergency, press the emer-
gency stop button on the control panel.
After remedying the fault, unlock the button by pulling it out before
restarting.
After emergency shutdown of the compressor, it can only be re-
started again no sooner than 10 minutes later.
Press button
”Shutdown“ on the control panel. The compressor stops. LCD display is
switched off. Close the air outlet valve. Switch off the voltage.

Содержание

Скачать