7. If the air used for cooling equipment is used while the facility is being heated, undertake
measures for it to be ltered so that it is suitable for breathing.
8. Regularly check that:
• safety devices and attachments are in place;
• all hoses and pipes are in good condition and sealed;
• there are no leaks;
• brackets and structural components are tightened;
• all electrical cables and contacts are in good condition and safe to use;
• safety devices are fully functional and there is no contamination etc;
• all structural components are in working order, with no signs of wear and tear.
1.5 Safety precautions for maintenance and repair
The user is solely liable for injuries or damages which occur due to
non-compliance with safety guidelines during installation, operati-
on or servicing, as well as unauthorised use of equipment!
1. Only original spare parts and ancillary items may be used. Using spare parts from other
manufactures may lead to unpredictable results and consequently accidents.
2. When performing installation and repair work, always wear goggles!
3. Before connecting or disconnecting equipment, disconnect it from the main pneumatic
system. Ensure that the hoses aren’t under pressure!
4. Before beginning installation or other work, ensure that equipment is not pressurised.
Installation work must not be carried out on equipment under pressure.
5. All maintenance work should be carried out only when the temperature of all structural
elements falls to room temperature.
6. Never use highly ammable solvents or carbon tetrachloride for cleaning structural ele-
ments. When wiping, take precautions against the poisonous vapours of cleaning uids.
7. When carrying out installation and repair work, an information plate should be afxed to
the control panel to warn against unauthorised start-up. For example, “Do not turn on. Per-
sonnel operating!”
8. The operator remotely controlling equipment must ensure that no installation or other
work is being performed with the equipment at that moment! An information plate must be
afxed to the equipment in relation to this: See 1.3.9.
9. Maintain cleanliness in the facility where the equipment is installed. Close open inlets and
outlets during installation with dry clothes or paper to prevent rubbish entering the equipment.