SNR S2989G-24TX-POE [433/553] Fault switchover
S2989G-24TX Operation Manual
Chapter 7 Reliability Configuration
7-34
7.5.1.2.1 Fault Switchover
The following is the single-ring and single link fault.
Figure 7-15 single-link fault
The steps of fault switchover:
a) The ring network status is normal; RPL owner node of G sends the R-APS (NR,
RB) packet periodically. This packet explains that RPL link is in blockade status
and the ring network is healthy.
b) There is fault on the link between node C and D.
c) The node C and D detected the fault, they block the port which connected to the
fault link respectively and run the flush FDB.
d) At the same time, the node C and D send the fault notification packet of R-APS
(SF) respectively through the port connected to the ring network.
e) All the nodes which received R-APS (SF) packet will run the flush FDB. At the
same time, RPL owner node of G and RPL neighbor node of A will configure the
RPL connection port as forward. The node G will stop sending R-APS (NR,RB)
packet.
f) Because RPL link has removed the blockade, all nodes can receive two R-APS
(SF) packets (sent by node C and D). after receiving the new R-APS (SF) packet,
it will run the flush FDB.
g) Link fault message of R-APS (SF) will transmitting always in the ring network.
7.5.1.2.2 Failure Recovery
When the ring link restored, there are two methods on the ring nodes: one is
Revertive switch. After the ring link restored to be normal, the ring network will block the