SNR S2989G-48TX-RPS — руководство по отладке и диагностике сетевых технологий [477/553]

Превью страниц Страница 477 / 553
SNR S2989G-24TX [477/553] Rspan troubleshooting
S2989G-24TX Operation Manual
Chapter 8 Debugging and Diagnosis Configuration
8-30
Switch(Config-If-Ethernet1/0/10)#exit
8.7.4
RSPAN Troubleshooting
Due to the following reasons, RSPAN may not function:
Whether the destination mirror port is a member of the Port-channel group. If so,
please change the Port-channel group configuration;
The throughput the destination port is less than the total throughput of the source
mirror ports. If so, the destination cannot catch all the datagrams from every source
ports. To solve the problem, please reduce the number of the source ports, or mirror
only single direction data flow, or choose some other port with higher capacity as the
destination port.
Between the source switch and the intermediate switch, whether the native VLAN of
the TRUNK ports is configured as RSPAN VLAN. If so, please change the native
VLAN for the TRUNK ports.
After configured RSPAN, the vlan tag will be added on the packet of the egress mirror.
It will cause the abort error frame on the reflection port, so the default MTU value of
the switch should be modified.
8.8
sFlow
8.8.1
Introduction to sFlow
The sFlow (RFC 3176) is a protocol based on standard network export and used on
monitoring the network traffic information developed by the InMon Company. The
monitored switch or router sends date to the client analyzer through its main operations
such as sampling and statistic, then the analyzer will analyze according to the user
requirements so to monitor the network.
A sFlow monitor system includes: sFlow proxy, central data collector and sFlow
analyzer. The sFlow proxy collects data from the switch using sampling technology. The
sFlow collector is for formatting the sample data statistic which is to be forwarded to the
sFlow analyzer which will analyze the sample data and perform corresponding measure
according to the result. Our switch here acts as the proxy and central data collector in the
sFlow system.
We have achieved data sampling and statistic targeting physical port.
Our data sample includes the IPv4 and IPv6 packets. Extensions of other types are
not supported so far. As for non IPv4 and IPv6 packet, the unify HEADER mode will be