SNR S2989G-48TX-RPS Руководство по настройке онлайн [447/553] 747284

Превью страниц Страница 447 / 553
SNR S2989G-48TX-RPS Руководство по настройке онлайн [447/553] 747284
S2989G-24TX Operation Manual
Chapter 7 Reliability Configuration
7-48
packet but not the user business packet; it improves the security of ERPS protocol.
User ensures the uniqueness of the configuration. This VLAN is as the vlan tag
when sending R-APS packet. In the instance, the protection VLAN configuration of
all nodes must be consistent.
We suggest the port which user configured on ERPS node is trunk port and ensure
that the vlan and control vlan that data packet is in are in the protection instance
and ERPS only protect the data and protocol packet in the instance. For instance,
the switch enables a protocol (CFM, EFM, Layer3 interface) and it makes the
switch send the protocol packet out. Then, if the vlan ID which sends the packet is
not in the protection instance, there will be the loop in the topology.
If configure the port status test method as fastlink, the hardware must support
fastlink function. Break off the notification of port status changing; disable the mac
soft study function at the same time.
If it is configured associating with CFM, the hardware must support CC function
and it can achieve the ability of CCM sending packet in 3.3ms.

Содержание