Luxstahl MARCO SP9 Head [8/16] Information
![Luxstahl MARCO SP9 Head [8/16] Information](/views2/1995721/page8/bg8.png)
8
INFORMATION
Display Information Descriptions
Description
Machine off. Display backlight off but temperature read-out still working.
Water level below low level probe. Machine is filling automatically.
Status LED – 2 red blinks.
Water level below low level probe. Machine has to be refilled manually
(shown only in MANUAL mode). Status LED – 2 red blinks.
Water is being heated. Dispense valve disabled.
Water is up to the temperature and can be used. Note that this only
means that the tank is heated and not that it is full. Status LED – green.
Water is being dispensed. If machine is set to time dispenses – there
will also be a progress bar drawn underneath. Dispense can always be
cancelled by clicking the dispense button again.
Machine was set by the user to a lower temperature than the current
tank temperature and is trying to cool down by taking in more cold
water. This process may take between 20 seconds to a few minutes
depending on tank size and temperature difference. Works only in
COOL FILL mode.
Machine cannot take more cold water to cool the tank because it is full.
Water needs to be dispensed to allow room for more cold water to come
in and finish cooling process.
Descale timer elapsed. Time to descale the tank.
Litres output exceeds set value. Time to change the water filter.
Low water level probe broken (disconnected). Machine detects high
level probe signal but cannot detect low level one. Filling is disabled.
Status LED – 1 red flash.
Temperature sensor (thermistor) is short circuited.
Dispense and heater disabled. Status LED – 3 red flashes.
Heating element is broken. Error is triggered when after 20 minutes of
heating and not taking in water temperature in the tank fails to increase.
Dispense is disabled. Status LED – 4 flashes.
Temperature sensor (thermistor) is disconnected.
Dispense and heater disabled. Status LED – 5 red flashes.
Incoming water pressure too low. The error will be reset after water
supply restores.All boiler functions are active. Status LED – 6 flashes.
Display board lost communication with boiler PCB (cannot receive serial
data about temperature and probes). All actions cancelled.
Status
Boiler Off
Filling...
Fill the Tank
Wait...
Boiler Ready
Dispense
Cooling...
Dispense water
to cool the tank
Descale Tank
Change Filter
Check Low Probe
Thermistor S/C
Element Failure
Thermistor O/C
Low Pressure
Comm Error
Содержание
Похожие устройства
- Luxstahl MARCO Qwikbrew-Twin Руководство по эксплуатации
- Luxstahl MARCO Qwikbrew Руководство по эксплуатации
- Luxstahl MARCO Maxibrew-Twin Руководство по эксплуатации
- Luxstahl MARCO Qwikbrew-6 Руководство по эксплуатации
- Luxstahl MARCO Jet 6 5, 6 кВт Руководство по эксплуатации
- Luxstahl MARCO Jet 6 2, 8 кВт Руководство по эксплуатации
- Midea MF517SNW Руководство по эксплуатации
- Luxstahl MARCO ECOBOILER T10 Руководство по эксплуатации
- Luxstahl MARCO Jet 6 + Urn + FCG6 Руководство по эксплуатации
- Luxstahl MARCO Bru F60M Руководство по эксплуатации
- Luxstahl MARCO Bru F45M Руководство по эксплуатации
- Luxstahl MARCO Ecoboiler UC45(8.4kw) Руководство по эксплуатации
- Luxstahl MARCO Bru F45A Руководство по эксплуатации
- Luxstahl MARCO Bru F60A Руководство по эксплуатации
- Luxstahl MARCO Ecosmart PB10 Руководство по эксплуатации
- Lofra DOLCEVITA 900 RR Руководство по эксплуатации
- Lofra DOLCEVITA 900 NM Руководство по эксплуатации
- Lofra DOLCEVITA 900 IN Руководство по эксплуатации
- Lofra DOLCEVITA 900 BI Руководство по эксплуатации
- Liebherr SK 4240 Руководство по эксплуатации