Before You Begin
STRIKE P38 User Manual Rev. 1
Safety Notes
Read all the following safety notes before working with this product. These notes contain important
information about the installation, usage, and maintenance of this product.
Personal Safety
• Avoid direct eye exposure to the light source while the product is on.
• Always disconnect the product from the power source before cleaning or replacing the fuse.
• Always connect the product to a grounded circuit to avoid the risk of electrocution.
• Do not touch the product’s housing when operating because it may be very hot.
Mounting and Rigging
• Do not submerge this product (IP65). Temporary outdoor operation is fine.
• When using this product in an outdoor environment, use IP65 (or higher) rated power and data
cables. Secure unused power and data ports with attached IP65 covers.
• CAUTION: When transferring product from extreme temperature environments, (e.g., cold truck to warm,
humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a
failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
• Not for permanent outdoor installation in locations with extreme environmental conditions. This
includes, but is not limited to:
• Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).
• Locations where the normal high or low temperatures exceed the temperature ranges in this
manual.
• Locations that are prone to flooding or being buried in snow.
• Areas where the product will be subjected to extreme radiation or caustic substances.
• Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent
surfaces.
• Make sure there are no flammable materials close to the product when operating.
• When hanging this product, always secure to a fastening device using a safety cable.
Power and Wiring
• Always make sure you are connecting the product to the proper voltage in accordance with the
specifications in this manual or on the product’s specification label.
• Never connect the product to a dimmer pack or rheostat.
• Never disconnect this product by pulling or tugging on the power cable.
Operation
• Do not operate this product if there is damage on the housing, lenses, or cables. Have the damaged
parts replaced by an authorized technician at once.
• Do not cover the ventilation slots when operating to avoid internal overheating.
• The maximum ambient temperature is 113 °F (45 °C). Do not operate the product at higher temperatures.
• The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
• The minimum ambient temperature is -22°F (-30°C). Do not operate the product at lower temperatures.
• In the event of a serious operation problem, stop using this product immediately!
Expected LED Lifespan
LEDs gradually decline in brightness over time, primarily because of heat. LEDs that are arranged in
clusters experience higher operating temperatures than single LEDs. For this reason, operating clustered
LEDs at their fullest intensity significantly reduces the LEDs’ lifespan. Under normal conditions, this
lifespan is 40,000 to 50,000 hours. If extending this lifespan is vital, lower the operating temperature by
improving the ventilation around the product, thus reducing the ambient temperature. In addition, limiting
the overall projection intensity may extend the LEDs’ lifespan.
This product contains no user-serviceable parts. Any reference to servicing in
this User Manual will only apply to properly trained, certified technicians. Do not
open the housing or attempt any repairs.
All applicable local codes and regulations apply to proper installation of this
product.
If your Chauvet product requires service, contact Chauvet Technical Support.
Содержание
- User manual 1
- Copyright notice 2
- Disclaimer 2
- Document printing 2
- Document revision 2
- Edition notes 2
- Intended audience 2
- Manual use 2
- Trademarks 2
- Ac power 3
- Before you begin 3
- Claims 3
- Configuration dmx 3
- Control options 3
- Control panel operation 3
- Description 3
- Dmx linking 3
- Dmx values 3
- Expected led lifespan 3
- Features 3
- Introduction 3
- Manual conventions 3
- Master slave connectivity 3
- Menu map 3
- Mounting 3
- Operation 3
- Product dimensions 3
- Product overview 3
- Programming 3
- Remote device management rdm 3
- Safety notes 3
- Symbols 3
- Table of contents 3
- What is included 3
- Configuration standalone 4
- Contact us 4
- Photometrics charts 4
- Product maintenance 4
- Returns 4
- Table of contents 4
- Technical information 4
- Technical specifications 4
- Before you begin 5
- Claims 5
- Manual conventions 5
- Page 1 of 16 5
- Symbols 5
- What is included 5
- Before you begin 6
- Expected led lifespan 6
- Mounting and rigging 6
- Operation 6
- Page 2 of 16 6
- Personal safety 6
- Power and wiring 6
- Safety notes 6
- Description 7
- Features 7
- Introduction 7
- Page 3 of 16 7
- Product overview 7
- Introduction 8
- Page 4 of 16 8
- Product dimensions 8
- Ac plug 9
- Ac power 9
- Dmx linking 9
- Dmx personalities 9
- Page 5 of 16 9
- Power linking 9
- Remote device management rdm 9
- Master slave connectivity 10
- Mounting 10
- Mounting diagram 10
- Orientation 10
- Page 6 of 16 10
- Procedure 10
- Rigging 10
- Control options 11
- Control panel operation 11
- Menu map 11
- Operation 11
- Page 7 of 16 11
- Programming 11
- Configuration dmx 12
- Control personalities 12
- Operation 12
- Page 8 of 16 12
- Starting address 12
- Dmx values 13
- Operation 13
- Page 9 of 16 13
- Auto programs 14
- Configuration standalone 14
- Operation 14
- Page 10 of 16 14
- Red shift 14
- Static mode 14
- Back light 15
- Dimmer profiles 15
- Factory reset 15
- Led frequency 15
- Master slave 15
- Operation 15
- Page 11 of 16 15
- System information 15
- Page 12 of 16 16
- Product maintenance 16
- Technical information 16
- Dimensions and weight 17
- Light source 17
- Ordering 17
- Page 13 of 16 17
- Photometrics 17
- Technical specifications 17
- Thermal 17
- Page 14 of 16 18
- Photometrics charts 18
- Strike p38 imperial 18
- Strike p38 metric 18
- Technical specifications 18
- Page 15 of 16 19
- Returns 19
- Contact us 20
- Europe 20
- General information technical support 20
- Mexico 20
- Page 16 of 16 20
- Strike p38 user manual rev 1 20
- Visit the applicable website above to verify our contact information and instructions to request support outside the u s united kingdom ireland mexico or benelux contact the dealer of record 20
- Website 20
- World headquarters 20
Похожие устройства
- CHAUVET SlimPar Q12 BT Руководство по эксплуатации
- CHAUVET Nimbus Руководство по эксплуатации
- CHAUVET COLORdash Par Hex 7 Руководство по эксплуатации
- Digitech JamMan Solo XT Руководство по эксплуатации
- CHAUVET SlimPAR Pro QZ12 USB Руководство по эксплуатации
- CHAUVET Freedom H1 X4 Руководство по эксплуатации
- CHAUVET Cumulus Руководство по эксплуатации
- CHAUVET COLORado 1-SOLO Руководство по эксплуатации
- Casio PX-870WE Руководство по эксплуатации
- Casio PX-770 BN Руководство по эксплуатации
- Casio PX-S1000BK Руководство по эксплуатации
- Casio PX-770 WE Руководство по эксплуатации
- Casio PX-770 BK Руководство по эксплуатации
- Casio PX-S3000BK Руководство по эксплуатации
- Casio SP-34 Руководство по эксплуатации
- Casio Privia PX-770BK Руководство по эксплуатации
- Casio GP-300WE Руководство по эксплуатации
- Casio GP-310 BK Руководство по эксплуатации
- Casio GP-310 WE Руководство по эксплуатации
- Casio LK-S250 Руководство по эксплуатации