00h 0 settings byte 1
MSB /
7 0
6 madi input: 0 = BNC, 1 = opt
5 madi frame: 0 = 48k, 1 = 96k
4 madi format: 0 = 56ch, 1 = 64ch
3 MSB / 1 madi channels: 0 = 1ff, 1 = 16ff,
2 LSB / 0 2 = 32ff, 3 = 48ff
1 0
LSB / 0
input madi / adat: 0 = madi, 1 =
adat
01h 1 settings byte 2
MSB /
7 0
6 MSB / 2
clock select: 0 = int 44.1, 1 = int
48, 2 = WCK
5 1 clock select: 3 = MADI, 4 = ADAT
4 LSB / 0 clock select
3
clock out: 0 = Fs, 1 = always sin-
gle speed
2 follow clock: 0 = off, 1 = on
1 MSB / 1
clock state: 0 = single speed, 1 =
ds, 2 = qs
LSB / 0 LSB / 0 clock state
02h 2 settings byte 3
MSB /
7 0
6 MSB / 1
analog level: 0 = +13, 1 = +19, 2 =
+24
5 LSB / 0 analog level
4 limiter: 0 = off, 1 = on
3 MSB / 1 Peak Hold: 0 = off, 1 = auto reset,
2 LSB / 0
Peak Hold: 2 = manual, 3 = reset
(tx only)
1 0
LSB / 0 lock keys: 0 = unlock, 1 = lock
03h 3 info byte 1
MSB /
7 0
6 MADI input override
5 MADI lock
4 MADI sync
3 MADI input 96k frame
2 MADI input 64ch
1
model subtype: 0 = M-16,
1 = M-32
LSB / 0 model subtype: 0 = AD, 1 = DA